PF6000X
Loop Detector Guide
Indicators
Power Indicator:
This LED indicator illuminates
when power is present.
Detect Indicator:
This LED indicator is illuminated
when there is a vehicle over the loop or the loop is
faulty. This LED can also be used to determine the
loop frequence. On reset, cunt the number of times
the LED flashes. Multiply this number by 10KHz. For
example: if the LED flashes 6 times, then the loop
frequency is between 60KHz and 70KHZ.
Loop Fault Indicator:
This LED indicator is
illuminated when the loop is either open circuit or
short circuit and is used to give a visual indication of
a faulty loop.