Parking and access control equipment manufactured in the UK
PF9700 Automated Hinge Gate
50.00
72.50
SUVEK1-A13
LOOP 1
Terminal Connector
Function Dip-Switches
'Fault/Detect' Red L.E.D.
'Power' Green L.E.D.
1
2
1
2
3
4
ON
LOOP
#1
TWISTED PAIR
CONNECTION
1 CHANNEL LOOP DETECTOR LAYOUT
Stock Code:
TST-SUVEK1
OPERATING INSTRUCTIONS
1. Turn OFF power to the control panel.
2. Plug the loop detector module into the pins provided on the motherboard of the control panel.
3.
Adjust the function Dip-Switches on the loop detector card as required.
Please refer to Dip-Switch Function Settings.
4. Turn ON power to the control panel.
5.
The green `Power` L.E.D. will flash continuously until the loop is tuned.
Once tuned, the green `Power` L.E.D. will illuminate constantly.
6. If a loop is faulty/not connected properly the red `Fault/Detect` L.E.D. will illuminate constantly.
7. If
a loop is covered the red `Fault/Detect` L.E.D. and the green `Power`
L.E.D. will illuminate together.
L.E.D. INDICATIONS
Detector is Tuning
Detector is Ready
Loop has Detected
Loop is Defective
Green Fast Flashing:-
Green ON Constantly:-
Green & Red ON Constantly:-
Red ON Constantly:-
50.00
72.50
LOOP 1
LOOP 2
Terminal Connector
'Power' Green L.E.D.
'Fault/Detect' Red L.E.D.
Function Dip-Switches
'Fault/Detect' Red L.E.D.
'Power' Green L.E.D.
SUVEK2-A13
1
2
ON
8
7
6
5
4
3
2
1
LOOP
#1
LOOP
#2
TWISTED PAIR
CONNECTIONS
2 CHANNEL LOOP DETECTOR LAYOUT
Stock Code:
TST-SUVEK2
DIP-SWITCH FUNCTION SETTINGS
Loop 1:
DIP-Switches 1 & 2:- Sensitivity (4 Steps)
DIP-Switch 3:- Holding Time (5 mins - Infinity)
Note:-
Loop will recalibrate after 5 minutes constant detection
DIP-Switch 4:- Frequency (High/Low)
1
3
4
MIN.
MAX.
1
3
4
2
2
1
1 2
2
= 5mins
= HIGH
= INFINITE
= LOW
ON
ON
ON
ON
Loop 2:
DIP-Switches 5 & 6:- Sensitivity (4 Steps)
DIP-Switch 7:- Holding Time (5 mins - Infinity)
Note:-
Loop will recalibrate after 5 minutes constant detection
DIP-Switch 8:- Frequency (High/Low)
5
7
8
5
7
8
6
6
5
5 6
6
ON
MIN.
ON
ON
MAX.
ON
= 5mins
= HIGH
= INFINITE
= LOW
DOOR
FEEDER CABLE IN TO
20mm PLASTIC CONDUIT
LOOP
min. 1.2m
LOOP
min. 1.2m
1.0m
2.0m
TYPICAL EXAMPLE OF LOOP INSTALLATION
INSTALLING A LOOP
Rubberised insulated wire of 0.75-1.50 sq.mm
(awg 20 - awg 16), preferably multi-stranded.
Note:-
High bed vehicles require larger loops.
Recommended depth to top of loop cable 25-50mm. (Maximum depth 65mm)
Loop slot
MUST
be sealed after cable has been installed and tested.
Use a flexible, weather proof sealant (i.e. Hot bitumen, Rubberised bitumen sealant).
CAUTION!
Never use cement / concrete, etc...
The feeder cable
MUST
be twisted a minimum 10 times
per meter & can be up to 250m long.
The loop must be placed at least 5m away from high tension cables and at least 1m away
from low tension cables. If the loop is placed in an area with reinforcing iron (typically a
concrete floor), the loop must be placed at least 50mm above the reinforcement.
If the detector is used for detecting high vehicles (lorries etc.) use only one loop for each
detector, otherwise it is possible to connect two loops to a single detector. Series coupling
the loops will give the largest sensitivity, parallel coupling gives the fastest reaction.
LOOP CABLE:
LOOP SIZE:
No. OF TURNS IN LOOP:
LOOP SLOT:
FEEDER CABLE:
LOOP PLACEMENT:
TWO or MORE LOOPS:
LOOP CIRCUMFERENCE
2 - 4m
4 - 7m
7 - 12m
12 - 25m
NUMBER OF TURNS
6
5
4
3
25-50mm
5-10mm
CONCRETE / TARMAC
BLOCK PAVING
BLOCK
SAND
BASE
PLASTIC CONDUIT WITH
LOOP CABLE INSIDE
LOOP
CABLE
SEALANT
14