Select a location for the air two ducts and louvered vents. It is recommended to position one vent high and
one vent low for optimal heating and cooling. Select a location in which the 3” duct hose will be easy to
conceal. A flat surface is required for through-mounting the louvered vents. Once two locations have been
selected:
1. Use the 3” hole saw to cut the holes where the vents will be located.
Do not
cut this hole larger than
3”; the vents will not fit correctly.
2. Use a 3 ½” hole saw to cut the holes that the ducting will pass through. Holes must be 3 ½”, 3” is not
large enough for duct hose to pass through.
3. Connect each of the duct hoses to the evaporator and tighten all the hose connections using the
included 3”worm gear clamps.
4. Route the hoses to the vents and tighten all of the hose connections using the included 3”worm gear
clamps.