41
GB/MT
13. Troubleshooting
Fault
Possible cause
Remedy
The compressor
does not start.
•
No supply voltage.
•
Insufficient supply voltage.
•
Outside temperature is too low.
•
Motor is overheated.
•
Check the supply voltage, the power plug and the
socket-outlet.
•
Make sure that the extension cable is not too long.
Use an extension cable with large enough wires.
•
Never operate with an outside temperature of below +5° C.
•
Allow the motor to cool down. If necessary, remedy
the cause of the overheating.
The compressor
starts but there is no
pressure.
•
The non-return valve (19) leaks.
•
The seals are damaged.
•
The drain plug for condensation water (10) leaks.
•
Contact your local service centre. Every attempt to carry
out a repair, can be dangerous if it is not done by skilled
personnel.
•
Check the seals and have any damaged seals re-
placed by a service center.
•
Tighten the screw by hand. Check the seal on the
screw and replace if necessary.
The compressor
starts, pressure is
shown on the pres-
sure gauge, but the
tools do not start.
•
The hose connections have a leak.
•
A quick-lock coupling has a leak.
•
Insufficient pressure set on the pressure regulator (5).
•
Check the compressed air hose and tools and replace
if necessary.
•
Contact your local service centre. Every attempt to carry
out a repair, can be dangerous if it is not done by skilled
personnel.
•
Increase the set pressure with the pressure regulator.