CAUTION!
Do not exceed the overvoltage category CAT III quoted.
Otherwise the multimeter could get damaged.
CAT III: Measurements within building installations (e.g. distribution boxes,
cabling, sockets and switches). This category also includes the following
two categories:
CAT II: Measurements on electrical and electronic devices supplied with
power via a mains plug.
CAT I: Measurements on electrical circuits with no direct connection to the
mains (battery-powered, car electrics, etc.).
CAUTION!
Before changing the measurement range, disconnect the
multimeter from the object it is measuring, otherwise it could get damaged.
CAUTION!
When using the measurement probes, connect the black
measurement cable to the COM connection first, then connect the red one.
When disconnecting, remove the red measurement probe first.
CAUTION!
Never connect a voltage source to the measurement probes
if it is set to continuity testing, resistance measurement, diode test, function
generator or current measurement. Otherwise the multimeter could get
damaged.
CAUTION!
Do not expose the multimeter to any direct heat sources (e.g.
heaters), direct sunlight or strong artificial light. The device must not be
exposed to spray or dripping water or abrasive liquids. Do not use the
multimeter near water. The multimeter must especially never be immersed
(do not place any containers containing liquids such as drinks, vases, etc.
on the multimeter). Make sure that the multimeter is not subject to excessive
shocks or vibrations. Do not introduce any foreign bodies into the device.
Otherwise the multimeter could get damaged.
5. Copyright
All the contents of this user manual are protected by copyright and provided to
the reader for information only. Copying data and information without the prior
explicit written consent of the author is strictly forbidden. This also applies to any
commercial use of the contents and information. All texts and diagrams are up-to-
date as of the date of printing.