PDAP 75 A1
GB
│
MT
│
83
■
Noise emission values
Noise measurement determined in accordance with ISO 15744:
Sound pressure level
L
pA
= 84 .1 dB(A)
Uncertainty K
pA
= 3 dB
Sound power level
L
WA
= 95 .1 dB(A)
Uncertainty
K
WA
= 3 dB
Wear ear protection!
Vibration emission value
Vibration values determined in accordance with ISO 28927-3 and
EN 12096:
a
h
= 0 .25 m/s
2
· Uncertainty K = 0 .52 m/s
2
WARNING!
►
The noise emission levels specified in these instructions have
been measured in accordance with the standardised measur-
ing procedure specified in ISO 15744 and can be used to
make equipment comparisons . The noise emission values vary
in accordance with the use of the compressed air tool and may
be higher than the values specified in these instructions in some
cases . It is easy to underestimate the noise emission load if the
compressed air tool is used regularly in a certain manner .
NOTE
►
For an accurate estimate of the noise emission load during a
certain working period, the times during which the appliance is
switched off or is running but not actually being used must also
be taken into consideration . This can significantly reduce the
noise emission load over the total working period .
Summary of Contents for 339152 1910