PDSS 310 B5
GB
│
CY
│
5
■
■
Switch off the tool when not in use .
■
Use personal protective equipment . Always
wear eye protection . Wearing protective equip-
ment such as a dust mask, non-slip safety shoes,
a helmet or hearing protection depending on
the type and use of the compressed air tool
reduces the risk of personal injuries .
■
Check all connections and supply lines . All
maintenance units, couplings and hoses must
correspond to the tool parameters in terms of
pressure and air flow . If the pressure is too low,
the function of the tool will be compromised
and if the pressure is too high, this can cause
property damage and personal injury .
■
Protect the hoses against kinking, constriction,
solvents and sharp edges . Keep hoses away
from heat, oil and rotating parts .
■
Ensure that the hose clamps are always tightened
firmly . Loose or damaged hose clamps can allow
air to escape in an uncontrolled manner .
■
Replace a damaged hose immediately . A de-
fective supply line can cause a compressed air
hose to thrash about and cause injuries .
■
If the power cable of this tool is damaged, it
must be replaced by the manufacturer or its
customer service department or by a similarly
qualified person in order to avoid hazards .
■
Do not use the tool if you are tired or under
the influence of drugs, alcohol or medication .
A moment of inattention when operating the
tool can result in serious injuries .
■
Do not inhale the exhaust air directly . Avoid
getting exhaust air in your eyes . The exhaust air
from the compressed air tool can contain water,
oil, metal particles or dirt from the compressor .
These can be hazardous to health .
WARNING!
►
BE CAREFUL WHEN PUTTING DOWN THE
TOOL! Always put the tool down in such a
way that it does not lie on the trigger . Under
certain circumstances, this might cause an
accidental activation of the tool, which in turn
might lead to hazards .
■
Only suitable accessories may be used . These
can be purchased from the manufacturer .
Failure to use original accessories can result in
hazards .
■
Use only filtered and regulated compressed air .
Dust, corrosive vapours and/or moisture can
damage the motor of a compressed air tool .
■
The hose must be designed for min . 6 .3 bar or
125 psi, corresponding to at least 150% of the
maximum pressure generated in the system .
■
The tool and the supply hose must be fitted with
a hose coupling that allows the pressure to be
relieved completely when the coupling hose is
disconnected .
■
DANGER! Avoid contact with live cables .
This tool is not insulated against electric shock .
WARNING! RISK OF INJURY!
►
At high working pressures, kickback forces
can occur . Under certain circumstances these
can cause hazards due to continuous loads .
■
If you are inexperienced with the tool, seek
training in how to use it safely .
WARNING! RISK OF INJURY!
►
RISK OF PUNCTURE WOUNDS! Do not
treat an injection wound as a simple cut .
A high-pressure jet can inject toxins into the
body and cause serious injuries . In the event
of injection into the skin, seek medical assis-
tance immediately .
■
The compressed air tool must not be modified in
any way without the manufacturer's approval .
■
Use the compressed air tool only at the specified
pressure .
■
The compressed air tool must always be discon-
nected from the air supply after use and for as
long as it is not in use .
■
The compressed air tool must not be used if it is
not airtight or if it requires repair .
■
Never connect the compressed air tool using a
compressed air hose whose pressure exceeds
6 .3 bar .
Summary of Contents for 345880 2004
Page 3: ...A...
Page 4: ...B C...
Page 34: ...PDSS 310 B5 30 RS...
Page 52: ...PDSS 310 B5 48 BG PDSS 310 B5 1 2 WARNING 1 2 3 4 5 6 7 8 9 0 q 1 4 w 1 4 e r 1 4 t 1 4 z...
Page 54: ...PDSS 310 B5 50 BG...
Page 55: ...PDSS 310 B5 BG 51 6 3 bar 125 psi 150...
Page 56: ...PDSS 310 B5 52 BG 6 3 bar...
Page 57: ...PDSS 310 B5 BG 53 ISO 11148...
Page 58: ...PDSS 310 B5 54 BG 4 Nm 10 Nm 60 Nm...
Page 59: ...PDSS 310 B5 BG 55...
Page 60: ...PDSS 310 B5 56 BG Whipcheck...
Page 61: ...PDSS 310 B5 BG 57 6 3 bar Liqui Moly 1 4 t 1 4 r 8 8 8 e 0...
Page 62: ...PDSS 310 B5 58 BG 1 4 w 8 1 4 q 6 3 bar 6 3 bar 5 bar 9 mm z 6 7 1 5 5...
Page 63: ...PDSS 310 B5 BG 59 4 1 2 3 4 2 2 F Fasten 2 R Release...
Page 64: ...PDSS 310 B5 60 BG a b 1 7 20 22 80 98...
Page 65: ...PDSS 310 B5 BG 61 3 112 115 s...
Page 70: ...PDSS 310 B5 66 GR CY PDSS 310 B5 1 2 WARNING 1 2 3 4 5 6 7 8 9 0 q 1 4 w 1 4 e r 1 4 t 1 4 z...
Page 72: ...PDSS 310 B5 68 GR CY...
Page 73: ...PDSS 310 B5 GR CY 69 6 3 bar 125 psi 150...
Page 74: ...PDSS 310 B5 70 GR CY 6 3 bar ISO 11148...
Page 75: ...PDSS 310 B5 GR CY 71...
Page 76: ...PDSS 310 B5 72 GR CY 4 Nm 10 Nm 60 Nm...
Page 77: ...PDSS 310 B5 GR CY 73...
Page 78: ...PDSS 310 B5 74 GR CY Whipcheck...
Page 80: ...PDSS 310 B5 76 GR CY 6 7 1 5 5 4 1 2 3 4 2 2 F Fasten 2 R Release...
Page 81: ...PDSS 310 B5 GR CY 77...
Page 82: ...PDSS 310 B5 78 GR CY a b 1 7 20 22 80 98 Kompernass Handels GmbH 3...