28
GB
IE
Trouble Shooting
Problem
Possible cause
Fault correction
Device does not start
Mains voltage not on
Check plug socket, cable, line and
plug, where appropriate, have re-
paired through electrical specialist
On/Off switch (6) or
deadman switch (4)
defective
Repair by Service Centre
Worn carbon brushes
Defective motor
Device runs with
interruptions
Power cable is damaged
Check the cable and have it
changed by the Service Centre if
necessary
Internal loose electrical
connection
Repair by Service Centre
On/Off switch (6) or
deadman switch (4) defec-
tive
Blades become hot
Blades (2) are blunt
Have the blades sharpened or
replaced (Service Centre)
Blades (2) are notched
Have the blades checked or
replaced (Service Centre)
Too much friction due to
lack of lubrication
Oil the blades (2)