17
GB/CY
• Selecting compressed air
supply
Press the selector switch for the compressed
air supply
10
in order to select the com-
pressed air source.
In INT position (Figure J) the compressed
air supply is provided by the integrated
compressor. In EXT position (Figure K) by
an external compressor.
When using the integrated compressor,
switch the toggle switch for external
compressed air
18
to the “closed”
position (Figure L).
• Procedure when using an
external compressor
PLEASE NOTE!
For plasma cutting, a pressure of
4–4.5 bar is recommended. Adjust this
accordingly on your compressor. Please
bear in mind that the pressure can lower
while setting the air pressure. Thus, in
a hose length measuring 10 m and an
internal diameter of 9 mm it drops by
approx. 0.6 bar.
The compressed air source must have a fi lter
and regulator.
Connect the compressed air hose
20
on
the back of the plasma cutter
1
to the
compressed air connection
17
. To do so,
insert the side of the compressed air hose
into the compressed air connection
17
of
the plasma cutter
1
without a quick
connector (see Fig. I).
The pressure can be adjusted using the
pressure regulator on your compressor.
Select a pressure of 4–4.5 bar.
In order to release the compressed air
hose
20
, you must press the locking
mechanism of the compressed air
connection
17
and pull out the com-
pressed air hose
20
at the same time
(see Fig. I).
Switch the toggle switch for external
compressed air
18
to the “open” position
(Figure M).
• Connecting the cutting torch
Insert the plasma burner plug
7
into the
plasma burner connection socket
13
and
tighten the plasma burner plug hand-tight
7
(see Fig. A+B).
Insert the plasma burner power plug
6
into the plasma burner power socket
11
and tighten the union nut hand-tight
(see Fig. A+B).
• Connecting the ground cable
Connect the ground terminal plug
5
with
the ground terminal - connection socket
12
.
Make sure that the connecting shaft is fi rst
connected and then turned. The connecting
shaft must face upwards when plugging in
the ground cable plug
5
. After plugging in,
the connecting shaft must be rotated in a
clockwise direction until it reaches the stop,
in order to lock it in place (see Fig. A+B).
This does not require force!
• Fitting the removable roller
guide (optional)
Push the removable roller guide
19
over the
nozzle clamping sleeve
8b
, until the locking
screws
19a
are completely above the black
area of the plasma burner
8
(behind the
gap at the back of the nozzle clamping
sleeve
8b
) (see Fig. A+B). Now fi x the
locking screws
19a
. The guide rollers
19c
are
now positioned such that the required
Before use
Summary of Contents for 360432 2010
Page 3: ...1 2 2 15 9 12 4 7 13 5 8 8a 3 5 6 7 8 4 6 11 8b 8c A B C D E 14 8 8a 8c 8b 10 ...
Page 4: ...8c 8c 8e 8d 8d 8b F G 17 16 18 J I N L M K H 19 19a 19c 19b 20 ...
Page 26: ...26 GB CY ...
Page 98: ...98 DE AT CH ...
Page 99: ...99 DE AT CH ...
Page 100: ...100 DE AT CH ...