Operation
Fitting the protective cover for cutting
When cutting with bonded abrasives, always use
the protective cover for cutting.
♦
Slide the protective cover onto the blade
guard (see fig. F) until the plastic clip
snaps into place at the end.
♦
To remove the protective cover , pull the
plastic clip slightly forwards to release the
protective cover .
Mounting/adjusting the blade guard
WARNING! RISK OF INJURY!
►
Always remove the plug from the power
socket before working on the appliance.
RISK OF INJURY!
►
Always use the angle grinder with the blade
guard
7
. The blade guard should be in-
stalled securely. Set it so that the highest
possible degree of safety is achieved, i.e. the
smallest possible part of the grinding disc is
exposed to the operator. The blade guard
7
is designed to protect the operator from frag-
ments and accidental contact with the
grinding tool.
RISK OF INJURY!
►
Make sure that the blade guard
7
is fitted
at least at the same angle as the additional
handle
6
(see fig. A). Otherwise, you could
cut injure yourself on the roughing disc or
cutting disc.
♦
Turn the blade guard
7
to the required position
(working position). Make sure that the blade
guard
7
is positioned in such a way that the
blade guard fixture
0
is lying over one of the
5 bulges
u
on the blade guard
7
(see fig. E,
fold-out page).
♦
Ensure that the blade guard fixture
0
is firmly
seated in the respective bulge
u
.
Fitting the additional handle
CAUTION!
►
For safety reasons, this appliance may only
be used with the additional handle
6
.
Failure to do so can lead to serious injury.
The additional handle
6
can be screwed
onto the left, the right or the top, depending
on the job at hand.
NOTE
►
You can leave the tool holder
6a
inserted
into the additional handle
6
or remove it as
desired.
Fitting/changing the roughing/
cutting disc
Always wear protective gloves when changing
cutting/roughing discs.
Roughing and cutting discs
become very hot. Allow them to cool down com-
pletely before touching them.
Pay attention to the dimensions of the roughing/
cutting disc. The diameter of the hole must fit the
mounting flange without any play. Do not use a
reducer or adapter.
■
Check the roughing/cutting disc. It should not
be damaged or damp and have no cracks.
Otherwise, it could break during use and cause
injuries.
NOTE
►
Use only discs which are free of dirt.
■
Use only grinding discs whose permissible
speed rating is at least as high as that on the
type plate on the power tool.
■
RISK OF INJURY!
Press the spindle locking
button
q
only when the mounting spindle
r
is
at a complete standstill.
♦
Press the spindle locking button
q
to lock the
gearbox.
♦
Loosen the clamping nut
e
using the two-hole
assembly key
z
(see fig. C).