PMFS 200 C3
■
42
│
GB
│
MT
WARNING! RISKS DUE TO DUST!
►
When working for extended periods of time
on wood and, in particular, materials that
produce dust which is hazardous to health,
connect the appliance to an appropriate
external dust extraction appliance .
Wear
safety goggles and a protective dust mask!
■
Ensure sufficient ventilation when working on
plastics, paints, lacquers, etc .
■
Do not soak the materials or the area to be
processed with liquids containing solvents .
■
Never work on moistened materials or damp
surfaces .
■
Avoid sanding lead paint or other harmful
materials .
■
Materials containing asbestos must not be
processed . Asbestos is a known carcinogen .
■
Avoid contact with the sanding sheet while the
appliance is running!
■
Do not use the appliance without a sanding
sheet fitted .
■
Never use the appliance for other purposes and
only use original parts/accessories . Using
attachments or accessory tools other than those
recommended in the operating instructions can
lead to a risk of injury .
■
Always allow the appliance to come to a
complete standstill before putting it down .
■
The appliance must always be kept clean, dry
and free from oil or grease .
Before use
Fitting/changing the sander plate
WARNING!
►
Always remove the plug from the mains
power socket before carrying out any work
on the appliance .
♦
Use the appropriate sander plate for
the corresponding application .
♦
Remove the four screws using the supplied
hex key .
♦
Remove the prefitted sander plate .
NOTE
►
The orbital sander plate can only be fitted
to the appliance in one direction . Please pay
attention to the arrow marks on the orbital
sander plate . These must point forwards .
With the delta sander plate the tip points
forwards .
►
The rubber pins have a groove on the side .
The groove must be aligned with the tabs in
the mounting holes on the respective sander
plate . This allows you to insert the
rubber pins into the sander plate .
♦
Now fit the required sander plate . Ensure that
the mounting plate
B
is aligned with the sander
plate . The threaded holes of the mounting plate
B
must be aligned with the corresponding holes
on the respective sander plate . Align the rubber
pins
A
(only on sander plates and )
with the holes in the appliance (see fig . 1) .
.
A
B
Figure 1
Summary of Contents for 367467-2101
Page 3: ...A B C ...
Page 4: ...D ...