7
GB/IE/CY
Technical data
Rated voltage:
230 V~ 50 Hz
Rated power:
270 W
Idling oscillation frequency: n
0
24000 min
-1
Idling speed:
n
0
12000 min
-1
Sanding plate:
ø 125 mm
Protection class:
II /
Noise and vibration data:
Measured values for noise are determined in ac-
cordance with EN 60745. The A-weighted noise
level of the electrical power tool are typically:
Sound pressure level:
83 dB(A)
Sound power level:
94 dB(A)
Uncertainty K:
3 dB
Wear ear protection!
Vibration total values determined according to
EN 60745:
Vibration emission value a
h
= 5 m / s
2
,
Uncertainty K < 1.5 m / s
2
.
WARNING!
The vibration level given in these
instructions has been measured in accordance with a
standardised measurement procedure specified in
EN 60745 and can be used to compare devices.
Different uses of the device give rise to different vibra-
tion levels and in many cases they may exceed the
values given in these instructions. It is easy to underes-
timate the vibration load if the electrical power tool is
used regularly in particular circumstances.
Note:
If you wish to make an accurate assessment
of the vibration loads experienced during a particu-
lar period of working, you should also take into ac-
count the intervening periods of time when the de-
vice is switched off or is running but is not actually
in use. This can result in a much lower vibration
load over the whole of the period of working.
General safety advice
for electrical power tools
WARNING!
Read all the safety advice
and instructions!
Failure to observe the safety
advice and instructions may result in electric shock,
fire and / or serious injury.
KEEP ALL THE SAFETY ADVICE AND INSTRUC-
TIONS IN A SAFE PLACE FOR FUTURE REFER-
ENCE! THE TERM “ELECTRICAL TOOL” USED
IN THE SAFETY ADVICE REFERS TO ELECTRICAL
TOOLS POWERED BY MAINS ELECTRICITY (BY
MEANS OF A MAINS LEAD) AND ELECTRICAL
TOOLS POWERED BY RECHARGEABLE BATTER-
IES (WITHOUT A MAINS LEAD).
1.
Workplace safety
a)
Keep your working area clean and
well lit.
Untidy or poorly lit working areas
can lead to accidents.
b)
Do not work with the device
in potentially explosive envi-
ronments in which there
are inflammable liquids, gases or
dusts.
Electrical power tools create sparks,
which can ignite dusts or fumes.
c)
Keep children and other peo-
ple away while you are op-
erating the electrical tool.
Distractions can cause you to lose control of
the device.
2.
Electrical safety
To avoid danger to
life from electric shock:
a)
The mains plug on the device must match
the mains socket. The plug must not
be modified in any way. Do not use
an adapter plug with devices fitted
with a protective earth.
Unmodified
plugs and matching sockets reduce the risk of
electric shock.
Introduction / General safety advice for electrical power tools
Summary of Contents for KH 3028 RANDOM ORBITAL SANDER