Operating the cordless
compressor PAK 16 A1
This appliance is not designed for continuous
operation. The appliance may be used for a maxi-
mum of 10 minutes continuous operation. If the
appliance overheats, remove the battery pack .
Allow the appliance to cool down completely and
then try using it again.
Display indicator
♦
Press the ON/OFF switch on the display
or press the ON/OFF switch to switch on
the display indicator .
♦
The last set pressure is displayed for 2 seconds.
♦
After two seconds, the current pressure of the
connected item is shown.
NOTE
►
If the compressed air hose is not connected
to a suitable item, the display indicator
shows "0".
♦
If the display indicator is switched on, you
can switch between "bar" and "psi" by pressing
the ON/OFF button .
♦
To switch off the display indicator , press the
ON/OFF button for 3 seconds.
NOTE
►
The compressor will not work if the display
indicator is switched off.
Setting the pressure
♦
Hold down the "+" or "–" button until the
display flashes.
♦
Press the "+" or "–" button to set the
desired pressure.
♦
Once you see the desired pressure on the
display indicator , do not press any button
for about 3 seconds.
The desired pressure is now set.
NOTE
►
The display indicator (and thus the com-
pressor) switches off after around three
minutes of inactivity.
TIP
►
If you press and hold the "+" or "–"
button, the pressure changes quickly.
Initial operation
♦
Loosen the cap nut (do not unscrew it com-
pletely!), twist in the compressed air hose
threaded connection
22a
and retighten the
cap nut .
♦
Select the desired pressure.
♦
Screw one of the supplied adapters ( , , ,
, , ) tightly onto the compressed air hose
adapter .
♦
Connect the adapter , , , , or
to the object to be inflated.
♦
Press the ON/OFF switch .
♦
The compressor switches off automatically when
you reach the preset pressure.
♦
Pull the adapter , , , , or out of
the now inflated item.
IB_280447_PAK16A1_PALP16A1_LB5.indb 51
16.11.16 13:28
Summary of Contents for PAK 16 A1
Page 3: ...CV_280447_PAK16A1 PALP16A1_LB5 indd 5 30 11 16 10 35...
Page 4: ...A 22a CV_280447_PAK16A1 PALP16A1_LB5 indd 8 30 11 16 10 35...
Page 18: ...PAK 16 A1 PALP 16 A1 14 ES IB_280447_PAK16A1_PALP16A1_LB5 indb 14 16 11 16 13 27...
Page 32: ...PAK 16 A1 PALP 16 A1 28 IT MT IB_280447_PAK16A1_PALP16A1_LB5 indb 28 16 11 16 13 27...
Page 46: ...PAK 16 A1 PALP 16 A1 42 PT IB_280447_PAK16A1_PALP16A1_LB5 indb 42 16 11 16 13 28...
Page 60: ...PAK 16 A1 PALP 16 A1 56 GB MT IB_280447_PAK16A1_PALP16A1_LB5 indb 56 16 11 16 13 28...
Page 74: ...PAK 16 A1 PALP 16 A1 70 DE AT CH IB_280447_PAK16A1_PALP16A1_LB5 indb 70 16 11 16 13 28...