PBH 1500 D4
9
GB
IE
NI
service line detector before
you start to cut or drill into
a surface.
Original accessories/
additional equipment
Only use the
accessories and
additional equipment
that are specified in the
operating instructions
and are compatible with
the appliance.
WARNING!
►
RISK OF INJURY! Switch
the device off and unplug
from the mains socket
before performing any
work on the device.
Initial operation
Additional handle
NOTE
►
For safety reasons, you should only use
this appliance with the additional handle
attached.
Loosen the additional handle by
turning it counter-clockwise direction.
Turn the additional handle to the
desired position.
Fix the additional handle in the new
position by turning it clockwise.
Depth stop
Push the depth stop locking button .
Insert the depth stop into the additional
handle .
Ensure that the toothing on the depth stop
is facing upwards and the scale is
facing outside.
Pull the depth stop out far enough
for the distance between the tip of the
drill and the tip of the depth stop to
correspond with the required drilling
depth.
Release the depth stop locking button
to tighten the depth stop .
Assembling tool/chuck:
Insert the tool/chuck in a twisting manner
into the tool holder until it latches itself
Checking the latch by pulling the tool/
chuck
Removing tool/chuck:
Push back the locking collar on the
machine backwards
Pull the tool/chuck out to remove.