PARKSIDE PDM 300 C3
English - 17
7.7 Continuity testing
CAUTION!
Make sure that all circuit components, circuits and parts to
be measured are disconnected and discharged. Otherwise the multimeter
could get damaged.
•
Connect the black measurement cable to the COM connection [4] and the
red measurement cable to the OUT INPUT connection [5].
•
Set the range selector switch [3] to the
position.
•
Connect the measurement probes [6] to the object to be measured.
•
If the resistance is under about 30 Ω, the buzzer sounds and the measured
reading is shown on the display [1].
7.8 Diode test
CAUTION!
Make sure that all circuit components, circuits and parts to
be measured are disconnected and discharged. Otherwise the multimeter
could get damaged.
•
Connect the black measurement cable to the COM connection [4] and the
red measurement cable to the OUT INPUT connection [5].
•
Set the range selector switch [3] to the
position.
•
Connect the red measurement probe [6] to the anode of the diode to be
tested and the black measurement probe [6] to the cathode.
•
The threshold voltage is shown in volts on the display [1]. If the display [1]
shows “OL”, the diode is being measured in the wrong direction or it is
faulty. Carry out a measurement in the opposite direction to check.