14. Troubleshooting
Fault
Possible cause
Remedy
The compressor does
not start.
Mains voltage is not available.
Check the cable, mains plug, fuse and socket.
Mains voltage is too low.
Make sure that the extension cable is not too long. Use an
extension cable with large enough wires.
Outside temperature is too low.
Never operate with an outside temperature of below +5 °C.
Motor is overheated.
Allow the motor to cool down. If necessary, remedy the cause
of the overheating.
The compressor starts but
there is no pressure.
The safety valve (19) leaks.
Contact your local service centre. Only allow qualified per-
sonnel to carry out repairs.
The seals are damaged.
Check the seals and have any damaged seals replaced by a
service centre.
The drain screw for condensate (10) leaks.
Tighten the screw by hand. Check the seal on the screw and
replace if necessary.
The compressor starts,
pressure is shown on the
pressure gauge, but the
tools do not start.
The hose connections have a leak.
Check the compressed air hose and tools and replace if
necessary.
A quick coupling has a leak.
Contact your local service centre. Only allow qualified per-
sonnel to carry out repairs.
Insufficient pressure set on the pressure
regulator (5).
Increase the set pressure with the pressure regulator.