PKZ 180 C3
■
18
│
GB
│
IE
Operation
NOTE
►
The appliance vibrates during operation .
Therefore, always put it down during opera-
tion . There are four feet on the bottom of
the appliance for this purpose .
♦
Remove the required accessories from the ac-
cessory compartment .
Switching on and off
Switching the appliance on:
♦
Move the ON/OFF switch into the position
"I" to switch the appliance on . The integrated
control lamp lights up . As soon as the pressure
has built up in the appliance, the appliance
switches itself off automatically .
Switching the appliance off:
♦
Move the ON/OFF switch into the position
"O" to switch the appliance off . The integrated
control lamp goes out .
CAUTION!
►
Caution! This appliance is not designed for
continuous operation.
To prevent the motor
from overheating, the appliance may only be
used as follows: within a period of 10 min-
utes the appliance may only be operated at
the rated power input for 15% of the period,
in other words, 1 .5 minutes . During the rest of
the time period (cooling phase 8 .5 minutes),
the appliance cools down again .
Compressed air hose with quick coupler
Connecting:
♦
Push the compressed air connector into the
quick coupler of the compressed air hose ,
the sleeve automatically springs forwards .
Cutting:
♦
Pull back the sleeve on the quick coupler of
the compressed air hose and remove the
compressed air connector .
CAUTION!
►
Caution!
When disconnecting the quick
coupler of the compressed air hose , hold
the coupler firmly to prevent injuries caused
by the hose flying off .
Inflation
with adapter
Schrader valve
Area of use:
This application allows for a simple and accurate
inflation . The manometer is used to check the
tire pressure . Thanks to the integrated release valve
it is possible to reduce the tire pressure if it is
too high .
ATTENTION!
►
Please note, the manometer is not cali-
brated! After inflation, always check the tire
pressure immediately, for example, at a petrol
station .
♦
Ensure that the ON/OFF switch is set to "O" .
♦
Press the lever quick coupler downwards to
attach it .
♦
Place the lever quick coupler onto the valve
and then release the lever .
♦
Insert the mains plug of the compressor into
a mains power socket .
♦
Switch the ON/OFF switch to "I" . The
integrated control lamp lights up . As soon as
the pressure has built up in the appliance, the
appliance switches itself off automatically .
♦
Pull the trigger . The appliance switches itself
back on automatically until the pressure in the
appliance has built up .
♦