Push the battery pack into the appliance.
♦
Switch off the charger for at least 15 minutes
between successive charging sessions. Also
disconnect the power plug from the mains
power socket.
Inserting/removing the battery
pack
Inserting the battery pack
♦
Allow the battery pack to click into place in
the appliance.
Removing the battery pack
♦
Press the release button and remove the
battery pack .
Checking the battery charge level
♦
Press the battery charge level button to
check the status of the battery (see also main
diagram). The status will be shown on the
battery display LED as follows:
RED/ORANGE/GREEN = maximum charge
RED/ORANGE = medium charge
RED = low charge – charge the battery
Using the appliance
Switching on/off
Switching on
♦
First, press the safety lock-out .
♦
Then press and hold the ON/OFF switch .
You can now release the safety lock-out .
Switching off
♦
Release the ON/OFF switch .
NOTE
►
For safety reasons, the ON/OFF switch
cannot be locked.
Setting the cut depth
Use the dial to adjust the cutting depth (0–2 mm)
in 1/10 mm increments using the cutting depth
scale . This can then be read via the marking.
Vacuuming dust/chips (see fig. A)
WARNING!
Always wear a dust mask!
RISK OF INJURY!
►
Always switch the appliance off and remove
the battery before carrying out any work on
the appliance.
Adjustable chip ejector (left/right)
♦
Unlock the chip ejector by turning it in the
opposite direction to the arrow (from the
"LOCK" position).
♦
Pull the chip ejector out of the appliance.
♦
The chip ejector can be attached to the
plane on the left or the right. Make sure that
the tab on the chip ejector fits into the
corresponding recess on the housing.
♦
Push the chip ejector into the appliance.
♦
Lock the chip ejector by turning it to the
position "LOCK".
External extraction
When using a workshop extractor, for example, it
may be necessary to use the adapter for external
extraction . The workshop vacuum cleaner must
be suitable for the material being processed.
Connection
♦
Push the adapter for external extraction
firmly onto the chip ejector .
♦
Push the hose of a suitable workshop vacuum
cleaner onto the chip ejector or the adapter
for external extraction , as applicable.
Removal
♦
Pull the hose of the workshop vacuum cleaner
off the chip ejector or the adapter.
♦
Pull off the adapter for external extraction ,
if attached.