20 GB/IE/NI
Problem
Possible cause
Action
The product works
with intermittent
operation.
o
Internal loose contact.
o
Have the product repaired by
the Service Centre.
o
The on/off switch
[
2]
is
defective.
The product
makes much
vibration and loud
noise.
o
The trimming assembly is dirty.
o
Clean the trimming assembly
(see “Cleaning and
maintenance”).
o
The motor is defective.
o
Have the product repaired by
the Service Centre.
The trimming result
is bad.
o
The line spool
[
]
does not have
enough cutting line.
o
Extend the cutting line if required
(see “Extending the cutting
line”).
o
Replace the line spool
[
]
(see “Cleaning and
maintenance”).
o
Both or one of the cutting lines
are not protruding out of the
spool cap
[
]
.
1. Remove the spool cap
[
]
.
2. Feed the cutting line through the
openings to the outside.
3. Reinstall the spool cap
[
]
.
o
The trimming assembly is dirty.
o
Clean the trimming assembly
(see “Cleaning and
maintenance”).
o
The battery
[
]
is not fully
charged.
o
Charge the battery
[
]
(see “Charging the battery”).
Cleaning and maintenance
m
WARNING! Risk of injury!
Always switch the product off,
remove the battery
[
]
and let
the product cool down before
performing inspection, maintenance
or cleaning works.
m
WARNING!
u
Risk of injury from moving dangerous
parts!
m
CAUTION!
u
Any maintenance and repair other than
described in this manual: Contact an
authorised service centre or a similarly
qualified person to check or repair the
product. Only use original parts.
NOTE
u
The following cleaning and servicing
should be done regularly. This will ensure
a long and reliable service life.
Cleaning
m
WARNING! Risk of electric shock!
u
Do not spray the product with water and
do not immerse it in water.
Summary of Contents for PRTA 20-Li D3