8
GB/IE
• Kinks where the connection cable has been improperly fas-
tened or routed.
• Places where the connection cables have been cut due to
being driven over.
• Insulation damage due to being ripped out of the wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not be used
and are life-threatening due to the insulation damage.
Check the electrical connection cables for damage regularly.
Ensure that the connection cables are disconnected from elec-
trical power when checking for damage.
Electrical connection cables must comply with the applicable
VDE and DIN provisions. Only use connection cables of the
same designation.
The printing of the type designation on the connection cable
is mandatory.
10.3 AC motor
• The mains voltage must be 230 V∼ 50 Hz.
• Extension cables up to 25 m long must have a cross-section
of 1.5 mm
2
.
Connections and repair work on the electrical equipment may
only be carried out by electricians.
Please provide the following information in the event of any
enquiries:
• Type of current for the motor
• Data of machine type plate
• Data of motor type plate
11. Cleaning, maintenance and storage
m
Attention!
Pull out the mains plug before carrying out any cleaning and
maintenance work! Risk of injury from electric shock!
m
Attention!
Wait until the equipment has cooled down completely! Danger
of burning!
m
Attention!
Always depressurise the equipment before carrying out any
cleaning and maintenance work! Danger of injury!
11.1 Cleaning
• Keep the device as free of dust and dirt as possible. Rub
the device clean with a clean cloth or blow it off with com-
pressed air at low pressure.
• We recommend that you clean the device directly after every
use.
• Clean the device at regular intervals using a damp cloth and
a little soft soap. Do not use aggressive cleaning agents or
solvents; they could attack the plastic parts of the device.
Make sure that no water can penetrate the device interior.
• The hose and injection tools must be disconnected from the
compressor before cleaning. The compressor must not be
cleaned with water, solvents or similar.
11.2 Maintaining the pressure vessel (fig. 1)
Attention!
To ensure a long service life for the pressure vessel (8), drain off
the condensate after each use by opening the drain screw (6).
Release the vessel pressure first (see 11.6.1).
Open the drain screw (6) by turning it anti-clockwise (looking
at the screw from the bottom of the compressor).
In order to drain the condensation water completely out of the
pressure vessel (8), it must be tilted slightly to the side so that
the drain screw (16) is the lowest point.
Then close the drain screw (6) again (turn it clockwise). Check
the pressure vessel (8) for rust and damage each time before use.
Do not use the compressor with a damaged or rusty pressure
vessel (8). If you discover damage, please contact the customer
service workshop.
11.3 Safety valve (fig. 7)
The safety valve (9) has been set for the highest permitted pres-
sure of the pressure vessel (8). It is not permitted to adjust the
safety valve (9) or remove the connection lock (9b) between
the exhaust nut (9a) and its cap (9c). Actuate the safety valve
(9) every 30 operating hours but at least 3 times a year to
ensure that it works when required. Turn the perforated exhaust
nut (9a) counterclockwise to open it and use your hands to pull
the valve rod outwards over the perforated exhaust nut (9a) to
open the outlet of the safety valve (9). Now, the valve audibly
releases air. Then, tighten the exhaust nut (9a) clockwise again.
11.4 Cleaning the air filter (fig. 8, 9)
The air filter (4) prevents dust and dirt being sucked in. It is es-
sential to clean this air filter (4) after at least every 300 hours
in service. A blocked air filter (4) significantly reduces the com-
pressor power.
Turn the air filter (4) counterclockwise to remove it. Open the
filter cover (4c) and remove it. You can now take out the filter
element (4b). Carefully tap out the filter element (4b), the filter
cover (4c) and the filter housing (4a). These components must
then be blown out with compressed air (approx. 3 bar) and
reassembled in reverse order.
11.5 Service information
With this product, it is necessary to note that the following parts
are subject to natural or usage-related wear, or that the follow-
ing parts are required as consumables.
Wearing parts*:air filter
* may not be included in the scope of supply!
11.6 Storage
m
Attention!
Pull out the mains plug and ventilate the equip-
ment and all connected pneumatic tools. Store the
compressor in such a way that it cannot be used by
unauthorised persons.
m
Attention!
Store the compressor only in a dry location which
is not accessible to unauthorised persons. Always
store upright, never tilted!