11
GB IE
NI
Additional safety instructions
• Connect the appliance only to a power
socket with a residual current circuit
breaker of rated residual current no
more than 30 mA.
• Keep power cords and extension cords
away from the disc. If they are damaged
or cut through, immediately pull the plug
from the outlet. Do not touch the cable
before it has been disconnected from the
power supply. Risk of electric shock!
• The replacement of the plug or the con-
nection line must always be executed
by the manufacturer of the electric tool
or his/her customer service in order to
avoid any hazards.
• Only use grinding discs where the in-
dicated rotational speed is at least as
high as what has been specified on the
name plate of the device.
• Carry out a visual inspection of the
grinding disc before use. Do not use
any damaged or deformed grinding
discs. Replace any damaged or worn
grinding discs.
• Make sure that the sparks produced by
grinding do not present a danger, e.g.
reach people or ignite flammable subs
-
tances.
• Always wear safety goggles, safety
gloves, respiratory protection and ear
protection when grinding, brushing and
cutting.
• Never keep the fingers between the
grinding disc and spark protection or in
close proximity to the protective hoods.
There is a risk of crushing.
• The rotating parts of the device cannot
be covered due to functional reasons.
Therefore, proceed cautiously and hold
the workpiece firmly in order to avoid
slipping which could cause your hands to
come into contact with the grinding disc.
• The workpiece gets hot during grin-
ding. Do not touch the machined area,
allow it to cool down. There is a risk of
burning. Do not use coolants or the like.
• If you are tired or have consumed al-
cohol or tablets, do not work with the
device. Always have a break on time.
• Switch the device off and remove the
mains plug
- to loosen a blocked insertion tool,
- if the connection line is damaged or
entangled,
- in case of unusual sounds.
RESIDUAL RISKS
Even if properly operating and handling
this electric tool, some residual risks will
remain. Due to its construction and build,
this electric tool may present the following
hazards:
a) Lung damage if suitable respiratory pro-
tection is not worn.
b) Hearing damage if suitable ear protec-
tion is not worn.
c) Damage to health due to
- touching the area of the grinding tool
which is not covered;
- ejection of parts of workpieces or
damaged grinding discs.
d) Health injuries which result from swin-
ging hand and arm, in the eve
nt that
the device is used over a longer period
of time or is not used and maintained
properly.
Warning!
During operation, this
electric tool generates an electro-
magnetic field which, under certain
circumstances, may impair the func-
tionality of active or passive medical
implants. To reduce the risk of seri-
ous or lethal injuries, we recommend
that persons with medical implants
Summary of Contents for PWS 125 C3
Page 3: ...1 2 3 4 8 9 7 5 6 11 12 13 14 19 18 17 22 21 20 15 16 25 24 23 10 3...
Page 45: ...45...
Page 46: ...46...
Page 48: ...48 2016 07 20 rev02 TR...