33
Natural Gas (G20) 2kPa
Product Code
No. of burners x Injector size
Auxiliary
Semi-Rapid
Fish Burner
Wok
AR 600
1 x 0.72
2 x 0.97
0
1 x 1.40
AR 600-LEG
1 x 0.72
2 x 0.97
0
1 x 1.40
AR 600-OBS
1 x 0.72
2 x 0.97
0
1 x 1.40
AR 600-WHT
1 x 0.72
2 x 0.97
0
1 x 1.40
AR 900
1 x 0.72
2 x 0.97
1 x 1.15
1 x 1.40
AR 900-LEG
1 x 0.72
2 x 0.97
1 x 1.15
1 x 1.40
AR 900-OBS
1 x 0.72
2 x 0.97
1 x 1.15
1 x 1.40
FS9S-5-2
1 x 0.72
2 x 0.97
1 x 1.15
1 x 1.40
Nominal Gas consumption per burner
3.6 MJ/h
6.3 MJ/h
10.08 MJ/h
13.7 MJ/h
General Product LPG (G30/G31) 2.75kPa
Product Code
No. of burners x Injector size
Auxiliary
Semi-Rapid
Fish Burner
Wok
AR 600
1 x 0.50
2 x 0.65
0
1 x 0.95
AR 600-LEG
1 x 0.50
2 x 0.65
0
1 x 0.95
AR 600-OBS
1 x 0.50
2 x 0.65
0
1 x 0.95
AR 600-WHT
1 x 0.50
2 x 0.65
0
1 x 0.95
AR 900
1 x 0.50
2 x 0.65
1 x 0.85
1 x 0.95
AR 900-LEG
1 x 0.50
2 x 0.65
1 x 0.85
1 x 0.95
AR 900-OBS
1 x 0.50
2 x 0.65
1 x 0.85
1 x 0.95
FS9S-5-2
1 x 0.50
2 x 0.65
1 x 0.85
1 x 0.95
Nominal Gas consumption per burner
3.6 MJ/h
6.3 MJ/h
10.08 MJ/h
13.7 MJ/h
Product Code
Max power consumption
AR 600, AR 600-LEG, AR 600-WHT, AR 600-OBS
2.65KW
AR 900, AR 900-LEG, AR 900-OBS
3.5KW
AR 600-CER
10.4KW
AR 900-CER
12.65KW
FS9S-5-2
4.35KW
This appliance must be installed by a suitably qualified and authorized person. The appliance must
be installed according to the electrical and gas standards of New Zealand.
Gas intake connection
½” BSP
Electricity supply
220-240V (50-60Hz)
TECHNICAL DATA