Remove the knob "M" which is simply inserted onto, tap stem.I Insert a small screwdriver "D" into the top shaft "C" and
turn the bypass screw left or right until flame of the burner is conveniently regulated to the low position.
Make sure that when turning quickly from "Full on" position to reduced rate position that the burner does not extinguish.
6. USER INSTRUCTIONS
1.To light the hotplate push In the appropriate control knob and turn anti-clockwise to the large
2.Keep the knob depressed until the burner lights.
3.Turn the tap to the required setting.
flame symbol (fig. 8).
BURNERS
NORMAL
RATE
INJECTOR
DIAMETER
DESCRIPTION
GAS
1/100 mm
1
2
3
4
SEMIRAPID
RAPID
68
111
145
90
AUXILIAR Y
52
87
3.6
3.6
6.3
6.3
13.7
13.7
10.8
10.8
103
162
TRIPLE
FLAME
MJ/h
Injector replacement
natural gas
natural gas
natural gas
Universal - LPG
Universal - LPG
Universal - LPG
natural gas
Universal - LPG
The final gas connection shall be made using a flexible hose or annealed copper tubing of sufficient length to permit the
insertion and removal of the appliance. For gas appliances connected using a flexible hose, install with a hose assembly that
complies with AS/NZ 1869 (Australian approved), 10mm ID class B or D, and in accordance with AS 5601. This hose must not
exceed 1.2m in length.
$*$
installed underneath or next to the cooktop. The hose should be positioned so that it does not interfere with drawers or other
moving parts, and so that it is not subjected to abrasion, kinking, or permanent deformation. The hose should be able to be
inspected along its entire length. Unions compatible with the fittings must be used and all connections must be tested.
` ;
point. The length of the chain or wire is not to exceed 80% of the length of the hose assembly.
+ |** $ ;
appliance, so that the gas supply to the appliance can be shut off in the event of an emergency or for servicing without having to
remove the appliance.
&$
appliance recess and must be readily accessible without having to remove the appliance.
COMMISSIONING PROCESS
The below process must be performed on the gas cooktop by the authorised plumber/gasfitter before leaving:
Z |@
Q
Q@ $$
FINAL INSTALLATION CHECKS
After commissioning and before leaving, the installer must check and ensure that:
` \ $* $ ]
$*
#$
* "+_"^>#
*
#* \$
adjustments involving any disconnection and reconnection), follow the below leak test procedure. Never use a naked flame to
%
In a small container, mix up a solution of water and detergent or soap. Make sure that the gas supply is turned on and all gas
control valves on the appliance are off. Using a brush or spray bottle, apply the solution to the gas line and each joint in the gas
line, including any flexible hosing and regulator. Bubbling of the solution will indicate that there is a leak present.
Retighten or reseal any joints that are leaking. If the leak persists, contact our after sales support centre for assistance.
6