background image

4590 Micro Reactors

w w w . p a r r i n s t . c o m

5

Explanation of Symbols

II

On position, full power heater switch

I

On position, half power heater switch

O

Off Position

~

Alternating Current (AC)

This 

CAUTION

 symbol may be present on the Product Instrumentation 

and literature. If present on the product, the user must consult the ap-
propriate part of the accompanying product literature for more infor-
mation.

This 

CAUTION

 symbol indicates that the surface may be hot.

Protective Earth (PE) terminal

. Provided for connection of the Protec-

tive Earth (green or green/yellow) supply system conductor.

Environmental Conditions

This instrument is intended to be used indoors.

Caution!

Do not use in hazardous atmospheres.

Operating:

 15 ºC to 35 ºC; maximum relative 

humidity of 80% non-condensing. 
Installation Category II (over voltage) in accordance 
with IEC 664. 
Pollution degree 2 in accordance with IEC 664. 

Altitude Limit:

 

2,000 meters.

Storage:

 -25 °C to 65 °C; 10% to 85% relative humidity.

Unpack Carefully

Unpack the equipment carefully and check all the 
parts against the packing list. If shipping damage 
is discovered, report it immediately to the deliver-
ing carriers. The vessel, motor, heater, and tem-
perature controller may be packed separately for 
convenience in shipping, but these parts are easily 
reassembled. Examine the components closely for 
any loose parts or shipping damage and be sure to 
check all layers of packing materials thoroughly so 
as not to overlook any parts which might otherwise 
be discarded.

Provisions for Lifting and Carrying

The 4590 and its components are very heavy. Before 
moving ensure all cables are disconnected. Use 
proper and safe lifting techniques when installing or 
moving the 4590 and/or its components. 

Cleaning & Maintenance

Periodic cleaning may be performed on the exterior 
surfaces of the instrument with a lightly dampened 
cloth containing mild soap solution. All power should 
be disconnected when cleaning the instrument.

There are no user serviceable parts inside the product 
other than what is specifically called out and discussed 
in this manual. Advanced troubleshooting instructions 
beyond the scope of this manual can be obtained by 
calling Parr Instrument Company in order to determine 
which part(s) may be replaced or serviced.

Ensure that any hot surfaces have had adequate 

time to cool before cleaning or maintaining 

the reactor and/or its components.

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for 4590

Page 1: ...s underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos...

Page 2: ...399M 4590 Micro BenchTop Reactors Operating Instruction Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 4: ...USE THE VESSEL 14 To open the Vessel 14 Before Closing the Vessel 14 Sealing Vessels with PTFE Gaskets 14 Sealing with Flexible Graphite Gaskets 14 O Ring Closures 14 Gas Connections 15 Pressurizing...

Page 5: ...e protection provided by the equipment may be impaired Safety Information To avoid electrical shock always 1 Use a properly grounded electrical outlet of correct voltage and current handling capabilit...

Page 6: ...ng carriers The vessel motor heater and tem perature controller may be packed separately for convenience in shipping but these parts are easily reassembled Examine the components closely for any loose...

Page 7: ...nvenient use in daily operation within certain temperature and pres sure limits using gaskets closures and other elements carefully selected for safe operation within the limits specified for that des...

Page 8: ...r Self Sealing O Ring Closure The flat gasket is held in a recess in the vessel head and a machine pilot on the cylinder closes the recess to completely contain the gasket The split ring closure used...

Page 9: ...ture since the strength of any material will normally fall off as the temperature is increased Temperature and pressure limits are also affected by the physical properties and temperature limits of th...

Page 10: ...the heater into the heater socket on the rear panel of the Series 4848 Reactor Controller 4 Plug the motor cord into the motor socket on the rear of the controller Secure the clamp on the motor cord w...

Page 11: ...id Sampling Valve The liquid sampling valve is attached to the same fitting as the gas inlet valve and connected to the same dip tube With this arrangement incoming gas is always introduced below the...

Page 12: ...under 1000 psi a relief valve is added and set to protect the gage A 1000 psi rupture disc is installed as the fail safe vessel protection For highly corrosive applications where the vapor phase might...

Page 13: ...con tinuous runs at high speeds the oiling rate should be increased to three drops per minute If the motor becomes sluggish flush it with a non flammable solvent in a well ventilated area Disconnect...

Page 14: ...Notes w w w p a r r i n s t c o m 13 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 15: ...flow under the loading pressure Routinely inspect cap screws on the split ring closure for lubrication and cleanliness It is important to clean and lubricate them periodically so that the required to...

Page 16: ...t ting gas so as not to exceed the maximum working limit Remember that any subsequent increase in temperature will raise the pressure Also be sure that the amount of liquid placed in the vessel is car...

Page 17: ...in place on the head before attaching any head fittings The compres sion ring cannot be installed after fittings have been screwed into the head 8 Clean all threads and gas passages thoroughly and re...

Page 18: ...usual occurrence raises any safety questions To return a vessel for repair contact Parr Instrument Company for a return authorization number RMA Apparatus returned for testing and overhaul should be s...

Page 19: ...lit Ring For parts made from alternate materials use the codes shown below as a suffix to the standard part number CM Alloy 400 CC Alloy 20Cb3 CT Alloy 600 CA Titanium G2 or G4 CG Alloy B 2 CH Alloy C...

Page 20: ...haft Impeller Assembly Part No Description Code A1987HC Shaft Impeller 25 50 mL SC A1987HC2 Shaft Impeller 100 mL SC A1987HC3 Shaft Impeller 25 50 mL RV A1987HC4 Shaft Impeller 100 mL RV A1987HC5 Shaf...

Page 21: ...C A451VB VALVE 555VBAD RED ADAPTER 154VB ELBOW A455HC S R ASSEMBLY 420HC2 ADAPTER A451VB VALVE 555VBAD RED ADAPTER 1401HC HEX RED NIPPLE A455VB2 VALVE A1120HC6 MAG DRIVE 836HC GAGE ADAPTER 593HC SERI...

Page 22: ...well 100 mL RV A2067HC5 Thermowell 25 50mL FH A2067HC4 Thermowell 100mL FH Dip Tube Part No Description Code 1443HC DipTube 25 mL 1443HC2 DipTube 50 mL 1443HC3 DipTube 100 mL Shaft Impeller Assembly P...

Page 23: ...C5 A2345HC5 1452HC12 NIPPLE HEX 1 4 NPTM ADAPTER SINGLE VALVE 1 4 NPTM DIP TUBE 50mL 2430HC19 A176VB COMPRESSION NUT SHORT SPLIT RING ASSEMBLY VALVE STRAIGHT A176VB A176VB AND LATCH HP HT ELBOW 1 4NPT...

Page 24: ...Gasket Flexible Graphite SR FG Thermowell Part No Description Code A2067HC5 Thermowell 25 50mL FH A2067HC4 Thermowell 100mL FH Dip Tube Part No Description 1443HC DipTube 25 mL 1443HC2 DipTube 50 mL...

Page 25: ...able Speed XP Explosion Proof Rated TW Thermowell HP HT High Pressure HighTemperature OVERARM PLATE OPTICAL WHEEL ENCASEMENT MOTOR RELEASE KNOB DRIVEN PULLEY BELT HUB ASSEMBLY SNAP RING ISOLATOR UPPER...

Page 26: ...SCREW 2224HC BELT GUARD STD 4 TW19NL LOCK WASHER OPTIONAL 845HC2 RELEASE KNOB 299HC2 BUSHING 328E7 HOLE PLUG A2223HC DRIVEN SHAFT ASSY 863HC COLLAR 2075HC2 COUPLING SN5013HX HEX NUT OPTIONAL A2262E T...

Page 27: ...7NL 2209HC BEARING 2187HC COUPLING FLEXIBLE SNAP RING 3 8 LOCK WASHER 4X SB1932BT06 10 32 X 3 8 BHSCS 2222HC DRIVE SHAFT 4X TW19NL LOCK WASHER 2226HC A3443HC BEARING HOUSING ASSEMBLY REF 2221HC HP VOL...

Page 28: ...4590MicroReactors w w w p a r r i n s t c o m 27 4593 Micro Reactor with Fixed Head Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 29: ...399M R06 01 22 15 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 30: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: