INSTRUCTION REF: IN100
ISSUE No. 6
DATE 06.06.16
Page 13 of 21
www.parry.co.uk
FAULT DIAGNOSTICS
The appliance will not work.
Check that the power switch is turned on to the appliance and the power is
in the on position.
Replace the fuse in the moulded plug (Only applies to AWB3).
o
If there is still a problem call engineer.
All other faults will be indicated by the lamp indicator on the front of the
appliance.
Table of indications are shown below:-
LED COLOURS
OPERATION / CONDITION
CYCLES THROUGH COLOURS
On initial power up. (Self Diagnostics)
YELLOW
Filling (Need to fill within 40 sec.)
BLUE
PURPLE
RED
Heat up cycle from power up.
RED
Boiler has reached operating temperature.
GREEN
Boiler needs de-scaling.
The boiler will still continue to work but unit must be
de-scaled in near future.
PURPLE
The boiler cannot get water from the supply quick
enough to achieve its full capacity
Check water supply is connected / turned on to unit.
Check that the inlet hose is not kinked or trapped.