INSTRUCTION REF: IN100             
ISSUE No.  6  
DATE  06.06.16 
Page 16 of 21  

 

www.parry.co.uk 

MANUAL ADJUSTMENT OF TEMPERATURE 
 
This appliance has been factory set to electronically regulate the 
temperature of the water. If due to any circumstance where the temperature 
of the water is too high or too low it can be adjusted manually. This does 
not require the need for a service engineer. 
 
 
 

 

To adjust the temperature 
 

A.

 

Remove the plastic blanking plug from the lower panel to show 
adjustment knob 

B.

 

To increase in temp turn slightly clockwise, to decrease in temp turn 
slightly anticlockwise. (It is important to be aware that too high a 
temp setting may lead to over boiling and may result in excessive 
steam venting from the outlet valve). 

C.

 

Replace the plastic blanking plug. 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for AWB3

Page 1: ...L DATA INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS EXPLODED VIEW PARTS LIST FAULT DIAGNOSTICS WIRING DIAGRAM WARRANTY INFORMATION DISPOSAL INFORMATION Customer Informatio...

Page 2: ...G MUST BE FITTED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT REGULATIONS The unit should be installed in compliance with the INSTALLATION INSTRUCTIONS and the NATIONAL REGULATIONS in force a...

Page 3: ...built to comply with the following standards BS EN 60335 1 WRAS Approved GENERAL INFORMATION Installation of water boilers must comply with the requirements of the water supply water fittings regulati...

Page 4: ...50 Hz Nominal Current 25Amps Nominal Wattage 6 kW Unit must be hard wired to suitable isolator spur Min Max water pressure 1 10 Bar Water Capacity 14 6 litres Dimensions mm 315 w X 505 d X 614 h Weigh...

Page 5: ...lement Parry Group Ltd strongly recommends that you use a food quality water softener or scale reducer Provide a water stop cock next the appliance Water Inlet Supplied with boiler The appliance is fi...

Page 6: ...event of component failure Parry Group Ltd strongly recommend that the overflow be plumbed to a suitable drain During operation there will be an occasional small discharge of steam and condensation f...

Page 7: ...nect the overflow pipe to the left hand side port Fit overflow to a suitable drain Remove red cap and connect water inlet hose Connect water inlet hose to BSP water connection Under no circumstances s...

Page 8: ...When the water level is reached the indicator lamp will then glow blue to indicate that the heating cycle has commenced As the temperature of water increases the indicator lamp will slowly change col...

Page 9: ...ecked for scale build up The frequency depends upon the hardness of the water the throughput and whether or not an effective water softener or scale reducer is fitted Disconnect the appliance from wat...

Page 10: ...s serviced every 12 months by a Parry authorised engineer Failure to service your product within the initial 12 month warranty period will cause the 24 month warranty to become void MAINTENANCE AND SE...

Page 11: ...INSTRUCTION REF IN100 ISSUE No 6 DATE 06 06 16 Page 11 of 21 www parry co uk EXPLODED VIEW VIEW AWB3 ONLY ADDITIONAL PARTS FOR AWB6 ARE SHOWN ON PAGE 10...

Page 12: ...NGLID AWB6 2 CONDENSING LID 14 3kW Element AWB3 2ELEM ELBW03000 15 Inlet Solenoid Hose AWB3 2SOLHOSE AWB3 2SOLHOSE 16 Overflow Steam Hose Assembly AWB3 2INNEROF AWB3 2INNEROF 16a Outlet Overflow Pipe...

Page 13: ...YELLOW Filling Need to fill within 40 sec BLUE PURPLE RED Heat up cycle from power up RED Boiler has reached operating temperature GREEN Boiler needs de scaling The boiler will still continue to work...

Page 14: ...ineer PURPLE RED FLASH The heater has failed to heat the tank in time Approx 15 minutes Call Engineer GREEN BLUE FLASH The water has failed to reach temperature in 120 minutes Call Engineer RED WHITE...

Page 15: ...INSTRUCTION REF IN100 ISSUE No 6 DATE 06 06 16 Page 15 of 21 www parry co uk WIRING DIAGRAM...

Page 16: ...or too low it can be adjusted manually This does not require the need for a service engineer To adjust the temperature A Remove the plastic blanking plug from the lower panel to show adjustment knob...

Page 17: ...has not been carried out in accordance with the manufacturer s instructions See installation details Also the misuse alteration or unauthorised repairs of the equipment will invalidate the warranty D...

Page 18: ...all warranty requests be submitted to Parry via email to warranty parry co uk It is at the discretion of PARRY whether to honour a service call which is out of the warranty period Not Covered Under Wa...

Page 19: ...iring junction box fault wrong fuse Any damages caused by the customer Lamps glass door gaskets Perspex baskets knobs all perishable items are not covered This appliance should be routinely serviced t...

Page 20: ...icates that this appliance may not be treated as household waste Instead it should be handed over to the applicable collection point for the recycling of electrical and electronic equipment Disposal m...

Page 21: ...ct the units manufacturer importer or their agent the contact details will be on the unit There will probably be a charge for this service which will depend on the physical size and location of the un...

Reviews: