Should vibration occur adjusting the fixing will help.
The canopy must have a minimum of 3 fixing per section.
Since all sites vary the ventilation outlet should be cut on site.
Internal fan
For canopies that have internal fans please ensure the fan is in the correct
position before attempting to mount the canopy to a wall.
The centrifugal fan used within the internal fan packs draws air from both sides,
so to work most effectively it has to be located centrally to give an even draw
across the length of the canopy. In the longer lengths two fans maybe required
and these are spread equally a third of the way along the canopy length.
Canopies with two fans require two sets of ducting, or a non return valve.