Canopy Light Fitting Instructions
Inset Light Box
If units were to be fitted into a ceiling or cupboard etc then the following size
holes would need to be cut to allow the unit to recess.
SLB700 = 685 x 130
SLB1000 = 985 x 130
SLB1300 = 1295 x 130
DLB700 = 685 x 255
DLB1000 = 985 x 255
DLB1300 = 1295 x 255
Surface Mount Light Box
There are fixing holes on the light box body that can be easily marked through
and drilled to fasten to the underside of the top of the canopy.
Bulk Head Light Box
Fixing holes can be drilled through the aluminium body allowing the light to be
attached in the required position on the underside of the top of the canopy.
To fix place the body on a firm surface and remove rear knockouts from inside
the body using a suitable punch, striking sharply
on the knockout near the periphery but away
from the securing tags.
Note: to maintain IP rating and weather proofing,
fitting a suitable gasket (rubber) should be used
when mounting on a BESA Conduit box
– fitted
by M4 screws through holes provided on rear of
fitting.