background image

 

INSTRUCTION REF: IN166 
ISSUE NO. 6 
DATE  - 21.03.16 
Page 13 of 24 

 

www.parry.co.uk 

 

Instruction Ref 

CONVIN34 

Issue No. 

Date updated 

07/09/2011 

        

NAT GAS - Conversion Instructions

 

 

Product 

 
P4BOP- Paragon 4 burner oven 

For use with models with the following serial numbers 
 

Model 

From 

To 

P4BOP-4 

11011813 

 

These instructions can be used for converting from LPG to Natural Gas 
 

LPG units are designed and tested in accordance with all current regulations 
enforced to run on the following gases only 

 

Nat Gas G20 @ 20mbar 8” W.G. 
Nat Gas G25 @ 25mbar 10” W.G. (Must be converted by manufacturers only)

 

PLEASE NOTE 

This conversion must be carried out by a Gas Safe Registered Engineer.

 

 

This conversion kit includes 

 

Description 

Product Code 

Quantity 

Hob valve 
bypass screw 

NAT hob valve bypass 
screw stamped with 85 

COPBPS-85 

Hob burner 
injector 

NAT hob valve  injector 
stamped with 185 

HOBINJECT185 

Oven valve 
bypass screw 

NAT oven burner injector 
stamped 
with 60 

COPBPS-60 

Oven burner 
injector 

NAT oven burner injector 
stamped with 150 

INJECT150 

Labels 

 

NAT GAS only + G20  1 

Instructions 

 

CONVIN34-4 

  

Summary of Contents for P4BO

Page 1: ...TION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS CONVERSION INSTRUCTIONS FAULT FINDING TECHNICAL DATA PARTS LIST SPARES LIST WARRANTY INFORMATION Customer Information MODEL NUMBER ___...

Page 2: ...ONS and the NATIONAL REGULATIONS in force at the time Particular attention should be paid to the Gas Safety Installation and Use Regulations and the Health and Safety at Work Act Each appliance requir...

Page 3: ...ance is suitable for gas supply available During installation provision must be provided for combustion air to the appliance through base and rear of appliance This should not be blocked at any time T...

Page 4: ...vel on the shelf in the oven not on the hotplate All four castors are adjustable To alter the height of the unit loosen the locking grub screw with an M3 allen key Next turn the large nut on the wheel...

Page 5: ...recommended An approved armoured flexible pipe may be used in conjunction with a straining cable Before the appliance is commissioned the gas safety regulations require that all connections on the ga...

Page 6: ...factory combustion and the pan is stable as it sits on the finger of the pan support Operating the oven 1 To light oven open door turn oven knob to approximate gas mark 5 and hold tap knob in at the s...

Page 7: ...for professional use by qualified people only There are no user serviceable parts Users should be made aware and take into consideration the danger of opening the oven door when the cooking chamber i...

Page 8: ...sured in an empty oven MARK 1 2 3 4 5 6 7 8 9 C 130 150 170 185 203 220 240 260 280 F 266 300 338 365 397 428 464 500 536 USAGE PRODUCT GAS TEMP HIGH TEMP ROASTING MEAT OR POULTRY 6 OR 7 LOW TEMP ROAS...

Page 9: ...gas supply Examine and clean all burner and flame retention ports Using a combination of brushes remove dust and lint from within the primary air ports venture and burners Check the burner aeration t...

Page 10: ...ry cleaners must be used with care they are highly corrosive and may cause damage to surfaces and components The stainless outer panels require a wipe down with warm soapy water DO NOT USE SCOURING PA...

Page 11: ...Burners will not stay alight Faulty connection at thermocouple valve incorrectly located Remake connection reposition thermocouple Burner goes out when turned to low Blockage in tap Clean and re greas...

Page 12: ...of tap Undo locknut on burner mounting channel Assemble in reverse order OVEN THERMOSTAT Proceed as for hob tap Slide thermostat phial from housing inside oven Remove through hole in the top of the ov...

Page 13: ...enforced to run on the following gases only Nat Gas G20 20mbar 8 W G Nat Gas G25 25mbar 10 W G Must be converted by manufacturers only PLEASE NOTE This conversion must be carried out by a Gas Safe Reg...

Page 14: ...with all current regulations enforced to run on the following gases only Propane G31 37mbar 14 8 W G PLEASE NOTE This conversion must be carried out by a Gas Safe Registered Engineer This conversion...

Page 15: ...ated from the gas supply before commencing conversion Please note P4BO only has four hob burners Remove pan support and burner caps Lift off aluminium burner plates Remove the solid top plate Using an...

Page 16: ...16 of 24 www parry co uk Remove the tap knobs to allow the fascia to unclip Remove low rate screws in tap body and replace with low rate screw from the conversion kit Converting the oven burner Unscre...

Page 17: ...t out of the burner Replace jet with the jet for the required gas Tighten up the 15mm nut Unwind the bypass screw on the oven valve and replace with the bypass screw for the required gas Connect the u...

Page 18: ...0 W G 4 973 KW 16966 Btu h GAS RATE m h ft h lb h kg h NATURAL G20 0 588 M HR 20 765 FT HR PROPANE G31 0 178 M HR 6 286 FT HR 0 691 LB HR 0 313 KG HR G25 25mbar 0 612 M HR 21 613 FT HR BURNER LOW RATE...

Page 19: ...T NATURAL G20 20mb 8 W G 29 059 kW 99148 Btu h PROPANE G31 37mb 14 8 W G 24 493 kW 83571 Btu h G25 25mb 10 W G 26 146 kW 89211 Btu h GAS RATE m h ft h lb h kg h NATURAL G20 3 075 m h 108 593 ft h PROP...

Page 20: ...INSTRUCTION REF IN166 ISSUE NO 6 DATE 21 03 16 Page 20 of 24 www parry co uk PARTS LIST MODEL P4B0 Side View Top View...

Page 21: ...8 x2 12 New hob front pipe FLEXT500X8 x2 13 Control knob ULTKNOB2 x4 14 Door handle P6BOHANDLE x1 15 Oven burner P4BOBURNER x1 16 New oven valve OVENVALVE x1 17 New oven thermocouple THCP320ISP x1 18...

Page 22: ...arranty During the warranty period it is at Parrys discretion to repair or replace the equipment Warranty only applies if the equipment has been used in a professional manor following the manufactures...

Page 23: ...s arranged for service call and engineer refused access or customer not there No faults with the machine Setting up of equipment eg dishwasher detergents levelling and setting up of doors on a 6 burne...

Page 24: ...ove will be forwarded to the parties responsible for placing the call Failure to pay any warranty charges will result in the customers warranty been put on hold until the bill has been settled Any iss...

Reviews: