Parry
-British Built for Purpose
IN270-2
12
Technical Instructions
High Rate Per Burner (All figures are NET)
High Rate Total Unit (All figures are NET)
Model
Injector Code
PGG6
Propane G31 @ 37mbar 14.8” W.G.
INJECT082
PGG6
Nat Gas G2
0 @ 20mbar 8” W.G.
INJECT130
Gas
Operating Pressure
Total Heat Input
NATURAL G20
20mb/8” W.G.
2.400 KW = 8190Btu/h
PROPANE G31
37mb/14.8” W.G.
2.726 KW = 9300 Btu/h
Gas Rate
M³/HR
FT³/HR
LB/HR
KG/HR
NATURAL G20
0.254
8.970
PROPANE G31
0.112
3.938
0.433
0.196
AIR FLOW RATE
FOR COMBUSTION
20m3/hr
3.18
112.3
Gas
Operating Pressure
Total Heat Input
NATURAL G20
20mb/8” W.G.
4.810 KW = 16412 Btu/h
PROPANE G31
37mb/14.8” W.G.
5.451 KW = 18599 Btu/h
Gas Rate
M³/HR
FT³/HR
LB/HR
KG/HR
NATURAL G20
0.509
17.975
PROPANE G31
0.223
7.875
0.865
0.392
AIR FLOW RATE
FOR COMBUSTION
20m3/hr
6.36
224.6