CONVERSION INSTRUCTIONS 

This conversion must be carried out by a competent qualified person. 

Natural to LPG 

1.

 

Remove fascia panel (2 screws underneath) 

2.

 

Remove fascia panel and disconnect ignition leads 

3.

 

Disconnect the gas feed at injector elbow. 

4.

 

Unscrew and remove aerator 

5.

 

Undo the back nut holding the injector elbow to the burner and remove 

6.

 

Remove natural injector and replace with the LPG injector issued 

7.

 

Re-assemble in the reverse order, refit the aerator. 

8.

 

Replace the existing labels and data plate with the LPG labels provided. 

9.

 

Low rate screw is on front L/H side of tap. 

10.

 

Low rate must be adjusted by inserting a small flat screwdriver and turning 
clockwise  to  the  stop.  This  must  only  be  done  by  a  qualified  corgi 
engineer, and as this setting has been factory sealed. Any alterations must 
be resealed. 

 

LPG to Natural 

1.

 

Remove fascia panel (2 screws underneath) 

2.

 

Remove fascia panel and disconnect ignition leads 

3.

 

Disconnect the gas feed at injector elbow. 

4.

 

Unscrew and remove aerator 

5.

 

Undo the back nut holding the injector elbow to the burner and remove 

6.

 

Remove LPG injector and replace with the natural injector issued 

7.

 

Re-assemble in the reverse order, refit the aerator. 

8.

 

Replace  the  existing  labels  and  data  plate  with  the  natural  labels 
provided. 

9.

 

Low rate screw is on front L/H side of tap. 

10.

 

Low  rate  must  be  adjusted  by  inserting  a  small  flat  screwdriver  and 
turning  clockwise  to  the  stop.  This  must  only  be  done  by  a  qualified 
corgi  engineer,  and  as  this  setting  has  been  factory  sealed.  Any 
alterations must be resealed. 

Model  

 

Injector Code 

PGG6 

Butane G30 @28mbar 11.2” W.G. 
Propane G31 @ 37mbar 14.8” W.G. 

INJECT082 

PGG6 

Nat Gas G20 @ 20mbar 8” W.G. 
Nat Gas G25 @ 25mbar 10” W.G. 

INJECT130 

PGG7 

Butane G30 @28mbar 11.2” W.G. 
Propane G31 @ 37mbar 14.8” W.G. 

INJECT099 

PGG7 

Nat Gas 

G20 @ 20mbar 8” W.G. 

Nat Gas G25 @ 25mbar 10” W.G. 

INJECT150 

Summary of Contents for PGG6

Page 1: ...S GRIDDLE INSTRUCTIONS MODEL PGG6 MODEL PGG7 VALIDATE WARRANTY SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS CONVERSION INSTRUCTIONS TECHNICAL DATA PART...

Page 2: ...ven easier to validate your warranty This can either be done by returning the warranty card supplied with every product or alternatively you can log onto our website at http www parry co uk contact us...

Page 3: ...hould be installed in compliance with the INSTALLATION INSTRUCTIONS and the NATIONAL REGULATIONS in force at the time Particular attention should be paid to the Gas Safety Installation and Use Regulat...

Page 4: ...d in for use with either Natural Gas or LPG Natural Gas appliances have an LPG conversion kit included as standard 2 All appliances must not be installed on or against any combustible surface 3 Cleara...

Page 5: ...as If a unit needs to be converted a qualified engineer must reseal the low rate adjuster after conversion 9 Remove all protective film before use 10 Ensure whoever is operating the appliance is fully...

Page 6: ...e pilot is now on If the unit fails to light within 1 minute abort the lighting process for at least 2 minutes to allow gas to disperse 5 Turn knob anti clockwise to obtain main gas The lowest setting...

Page 7: ...e it is recommended that the fascia is removed To do this take off the control knobs and remove 2 screws from the underside of the fascia panel Remove the nut from the underside of the griddle plate T...

Page 8: ...he nut holding the thermocouple at the rear of the gas cock and undo the nut at pilot burner Remove the faulty thermocouple Push the new thermocouple gently into the gas cock and tighten the nut Do no...

Page 9: ...01332 875536 Parry Group Limited Town End Road Draycott Derby England DE72 3PT www parry co uk Refit pilot supply Refit thermocouple and tighten do not over tighten Refit thermostat phial to plate Re...

Page 10: ...ualified corgi engineer and as this setting has been factory sealed Any alterations must be resealed LPG to Natural 1 Remove fascia panel 2 screws underneath 2 Remove fascia panel and disconnect ignit...

Page 11: ...72 FT HR 0 452 LB HR 0 205 KG HR PROPANE G31 0 112 M HR 3 938 FT HR 0 433 LB HR 0 196 KG HR G25 25mb 0 318 M HR 11 230 FT HR AIR FLOW RATE FOR COMBUSTION 20m HR 3 18M HR Total Unit All figures are NET...

Page 12: ...DE NUMBER OFF 1 Float Rail 600CHARGRILL X1 2 Flame Safety Gas Cock 8mm GASTAP8 1 X2 3 Burner BURNER001 X2 4 Burner Box BBOX2GRID X1 5 Thermocouple MBETCASSY X2 6 Spark Electrode MBETCASSY X2 7 HT Cabl...

Page 13: ...84 FT HR 0 575 LB HR 0 261 KG HR PROPANE G31 0 110 M HR 3 884 FT HR 0 444 LB HR 0 202 KG HR G25 25mb 0 425 M HR 15 007 FT HR AIR FLOW RATE FOR COMBUSTION 20m HR 150 07 FT HR Total Unit All figures are...

Page 14: ...ART PART CODE NUMBER OFF 1 Float Rail 750GASGRID X1 2 Flame Safety Gas Cock 8mm GASTAP8 1 X2 3 Burner BURNER001 X2 4 Burner Box X1 5 Thermocouple MBETCASSY X2 6 Spark Electrode MBETCASSY X2 7 HT Cable...

Page 15: ...X1 600CHARGRILL FLOAT RAIL PGG6 1 X1 BRACKET01 SADDLE BRACKET 9 X2 X2 NATURAL CONVERSION KIT CONSISTS OF INJECT130 NATURAL INJECTOR PGG6 14 X2 SET OF LABELS X1 IN103 4 INSTRUCTION PACK X1 LPG CONVERS...

Page 16: ...n or unauthorised repairs of the equipment will invalidate the warranty During the warranty period it is at Parrys discretion to repair or replace the equipment Warranty only applies if the equipment...

Page 17: ...her detergents levelling and setting up of doors on a 6 burner cooker Excessive carbon build up on griddle plates Over use of lava rock on the chargrills recommended use by Parry 2kg only Faulty elect...

Reviews: