background image

INSTRUCTION REF: IN103 
ISSUE NO. 6 

DATE 19.10.11. 

 

 

 

 

 

 

 

Page 7 of 17 

 
TELEPHONE: 

SERVICE (44) 01332 875665 

FAX:   

           SERVICE (44) 01332 875536 

 

Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT 

www.parry.co.uk 

MAINTENANCE INSTRUCTIONS

 

 

MAINTENANCE AND SERVICE MUST ONLY BE UNDERTAKEN BY 
REGISTERED FITTERS. 
 

Parry advise that regular annual maintenance should be conducted by a Gas 
Safe registered engineer. This is essential to maintain safety and prolong life of 
the appliance. 
 

PLEASE NOTE THE LOW RATE ADJUSTER ON THE UNIT HAS BEEN 
FACTORY SET AND SHOULD NOT BE ADJUSTED UNLESS BY A 
QUALIFIED ENGINEER IN WHICH CASE THE LOW RATE ADJUSTER 
SHOULD BE RE-SEALED. 

 
To facilitate maintenance it is recommended that the fascia is removed. To do 
this, take off the control knobs and remove 2 screws from the underside of the 
fascia panel. 
 
Remove the nut from the underside of the griddle plate. The plate can then slide 
forwards and be lifted off after withdrawing thermostat phials from underside of 
plate. 
 
Thoroughly clean the burner and burner chamber. 
 
Carefully clean the thermocouple probe, the ignitor, electrode and pilot jet. 
 
Reconnect the gas supply and check for gas soundness. 
 
Check that the flame safety device is operating by shielding the probe from the 
pilot flame until the device operates.  
 
Check that the spark ignites the gas. 
 
Thoroughly clean the plate and fat chute, and drawer. 
 
Replace the thermostat phial to its correct position and fasten the plate down to 
the body by tightening the nut. 
 
Refit fascia panel with the 2 screws and re-attach the control knobs. 
 

Summary of Contents for PGG6

Page 1: ...S GRIDDLE INSTRUCTIONS MODEL PGG6 MODEL PGG7 VALIDATE WARRANTY SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS CONVERSION INSTRUCTIONS TECHNICAL DATA PART...

Page 2: ...ven easier to validate your warranty This can either be done by returning the warranty card supplied with every product or alternatively you can log onto our website at http www parry co uk contact us...

Page 3: ...hould be installed in compliance with the INSTALLATION INSTRUCTIONS and the NATIONAL REGULATIONS in force at the time Particular attention should be paid to the Gas Safety Installation and Use Regulat...

Page 4: ...d in for use with either Natural Gas or LPG Natural Gas appliances have an LPG conversion kit included as standard 2 All appliances must not be installed on or against any combustible surface 3 Cleara...

Page 5: ...as If a unit needs to be converted a qualified engineer must reseal the low rate adjuster after conversion 9 Remove all protective film before use 10 Ensure whoever is operating the appliance is fully...

Page 6: ...e pilot is now on If the unit fails to light within 1 minute abort the lighting process for at least 2 minutes to allow gas to disperse 5 Turn knob anti clockwise to obtain main gas The lowest setting...

Page 7: ...e it is recommended that the fascia is removed To do this take off the control knobs and remove 2 screws from the underside of the fascia panel Remove the nut from the underside of the griddle plate T...

Page 8: ...he nut holding the thermocouple at the rear of the gas cock and undo the nut at pilot burner Remove the faulty thermocouple Push the new thermocouple gently into the gas cock and tighten the nut Do no...

Page 9: ...01332 875536 Parry Group Limited Town End Road Draycott Derby England DE72 3PT www parry co uk Refit pilot supply Refit thermocouple and tighten do not over tighten Refit thermostat phial to plate Re...

Page 10: ...ualified corgi engineer and as this setting has been factory sealed Any alterations must be resealed LPG to Natural 1 Remove fascia panel 2 screws underneath 2 Remove fascia panel and disconnect ignit...

Page 11: ...72 FT HR 0 452 LB HR 0 205 KG HR PROPANE G31 0 112 M HR 3 938 FT HR 0 433 LB HR 0 196 KG HR G25 25mb 0 318 M HR 11 230 FT HR AIR FLOW RATE FOR COMBUSTION 20m HR 3 18M HR Total Unit All figures are NET...

Page 12: ...DE NUMBER OFF 1 Float Rail 600CHARGRILL X1 2 Flame Safety Gas Cock 8mm GASTAP8 1 X2 3 Burner BURNER001 X2 4 Burner Box BBOX2GRID X1 5 Thermocouple MBETCASSY X2 6 Spark Electrode MBETCASSY X2 7 HT Cabl...

Page 13: ...84 FT HR 0 575 LB HR 0 261 KG HR PROPANE G31 0 110 M HR 3 884 FT HR 0 444 LB HR 0 202 KG HR G25 25mb 0 425 M HR 15 007 FT HR AIR FLOW RATE FOR COMBUSTION 20m HR 150 07 FT HR Total Unit All figures are...

Page 14: ...ART PART CODE NUMBER OFF 1 Float Rail 750GASGRID X1 2 Flame Safety Gas Cock 8mm GASTAP8 1 X2 3 Burner BURNER001 X2 4 Burner Box X1 5 Thermocouple MBETCASSY X2 6 Spark Electrode MBETCASSY X2 7 HT Cable...

Page 15: ...X1 600CHARGRILL FLOAT RAIL PGG6 1 X1 BRACKET01 SADDLE BRACKET 9 X2 X2 NATURAL CONVERSION KIT CONSISTS OF INJECT130 NATURAL INJECTOR PGG6 14 X2 SET OF LABELS X1 IN103 4 INSTRUCTION PACK X1 LPG CONVERS...

Page 16: ...n or unauthorised repairs of the equipment will invalidate the warranty During the warranty period it is at Parrys discretion to repair or replace the equipment Warranty only applies if the equipment...

Page 17: ...her detergents levelling and setting up of doors on a 6 burner cooker Excessive carbon build up on griddle plates Over use of lava rock on the chargrills recommended use by Parry 2kg only Faulty elect...

Reviews: