LUBRICATION AND MAINTENANCE INTERVAL SCHEDULE
EVERY 1000 HOURS OR 2 YEARS REPLACE HYDRAULIC OIL AND PRESSURE FILTER
-
Let the sweeper work until the hydraulic oil is little warm
-
Turn off the machine, turn off the main power switch
-
Unscrew the bottom plug (
A
) from the hydraulic tank and drain the oil
-
Loosen the lid (
B
) and clean the tank internally
-
Clean and install the bottom plug (
A
)
-
Replace the breathing filter (
C
)
-
Unscrew the filter bowl (
D
)
-
Replace filter element (
E
)
-
Fill the oil tank with filtered hydraulic oil through the oil filling tube (
C
)
-
Turn on the main switch start engine
-
Let machine work for 10-15 minutes and check for leakage, if necessary, add
additional oil. Level should be in the middle of the level glass (
F
)
If the oil is replaced due to contamination, the oil tank, hydraulic hoses and all
hydraulic components must be thoroughly clean with cleaning oil before filling new oil
To avoid burning your hands, do not do this while the hydraulic oil is hot
Every 1000 hours or 2-year service should return at intervals of every 1000 hours or 2 years
34