Read this manual carefully and completely before assembly! Always observe the general safety
instructions and the safety symbols with information in the text.
Hand out this manual to the user (tenants, proprietors, property management etc.) after comple-
ting assembly.
The packaging must be sorted before disposal. If you wish to dispose of the device, observe
the currently applicable regulations. The municipal office in charge will provide information.
Do not position the device above sensitive furniture, surfaces or pictures; the wall beneath the device
should remain unused.
Do not position the device above or near room thermostats.
The solid plastic outer covers provided by LUNOS ensure high resistance to driving rain and can be
used in Stress Group III pursuant to DIN 4108
-
3 (2012
-
04). Metal or metal
-
coated covers can be
used in Stress Group I pursuant to DIN 4108
-
3 (2012
-
04).
In the case of buildings exposed to wind or the risk of strong winds and rain to the outer covers, fur-
ther measures of weather protection may be required.
Note regarding LUNOS outer covers
About this manual
EN
Disposal
Installation position
Check the filter (1) every 3 months for contamination. Clean or replace, if required. After inserting the
filter, snap the design screen into place in “open position“.
The ventilation openings must not be covered or obstructed.
Note: Alternative inner screens are supplied with the corresponding instructions on filter re-
placement!
Filter replacement
Caution! Any assembly work (connection to power supply and setting of the miniature switches)
may only be carried out after disconnecting the supply voltage.
Make sure that the supply voltage of all connection lines is voltage
-
free (dead). (Separation from
the power supply with a minimum contact opening of 3 mm, e.g. electric fuse).
Each electric circuit of this ventilation system must be fitted with a residual current protection
(e.g. FI switch/RCCB).
Electric connection only by a specialist.
Additional installations and electrical components in the ventilation unit are not allowed.
Connection diagrams for further fan functions upon request.
Use the following cables for the electric connection:
Cable to the ventilation units: e.g. J
-
Y(St)Y(2x2x0,8), min. 0,5 mm², max. 1,5 mm²
Cable for the supply voltage of the power supply unit e.g. NYM 3 x 1,5 mm²
Electrical connection