Precision Interferometer

012-07137B

®

Equipment Return

Should the product have to be returned to PASCO
scientific for any reason, notify PASCO scientific by
letter, phone, or fax BEFORE returning the product.
Upon notification, the return authorization and shipping
instructions will be promptly issued.

  NOTE:

  NO EQUIPMENT WILL BE

ACCEPTED FOR RETURN WITHOUT AN
AUTHORIZATION FROM PASCO.

When returning equipment for repair, the units must be
packed properly. Carriers will not accept responsibility
for damage caused by improper packing. To be certain
the unit will not be damaged in shipment, observe the
following rules:

1. The packing carton must be strong enough for the

item shipped.

2. Make certain there are at least two inches of packing

material between any point on the apparatus and the
inside walls of the carton.

3. Make certain that the packing material cannot shift

in the box or become compressed, allowing the
instrument come in contact with the packing carton.

Address:

PASCO scientific
10101 Foothills Blvd.
Roseville, CA 95747-7100

Phone:

(916) 786-3800

FAX:

(916) 786-3292

email:

techsupp@pasco.com

web:

www.pasco.com

ii

Copyright Notice

The PASCO scientific 012-05187C Precision
Interferometer manual is copyrighted and all rights
reserved. However, permission is granted to non-profit
educational institutions for reproduction of any part of
the manual providing the reproductions are used only
for their laboratories and are not sold for profit.
Reproduction under any other circumstances, without
the written consent of PASCO scientific, is prohibited.

Limited Warranty

PASCO scientific warrants the product to be free from
defects in materials and workmanship for a period of
one year from the date of shipment to the customer.
PASCO will repair or replace at its option any part of
the product which is deemed to be defective in material
or workmanship. The warranty does not cover damage
to the product caused by abuse or improper use.
Determination of whether a product failure is the result
of a manufacturing defect or improper use by the
customer shall be made solely by PASCO scientific.
Responsibility for the return of equipment for warranty
repair belongs to the customer. Equipment must be
properly packed to prevent damage and shipped postage
or freight prepaid. (Damage caused by improper
packing of the equipment for return shipment will not
be covered by the warranty.) Shipping costs for
returning the equipment after repair will be paid by
PASCO scientific.

Copyright, Warranty, and Equipment Return

Please—

Feel free to duplicate this manual

subject to the copyright restrictions below.

Summary of Contents for OS-9255A

Page 1: ...Instruction Manual and Experiment Guide for the PASCO scientific Models OS 9255A thru OS 9258A 012 07137B PRECISION INTERFEROMETER Includes Teacher s Notes and Typical Experiment Results...

Page 2: ...ion 4 Michelson Twyman Green Fabry Perot Setup and Operation 6 Tips on Using the Interferometer 9 Sources of Error Troubleshooting Experiments Experiment1 IntroductiontoInterferometry 11 Experiment 2...

Page 3: ...ghted and all rights reserved However permission is granted to non profit educational institutions for reproduction of any part of the manual providing the reproductions are used only for their labora...

Page 4: ...vide asimpleintroductiontothisimportantapplicationof interferometry Fabry Perot The Fabry Perot Interferometer is also an important contemporary tool used most often for high resolution spectrometry T...

Page 5: ...Ocatalogfordetails Additional Equipment Recommended TheOS 9256AInterferometerAccessoriesincludes RotatingPointer VacuumCell ComponentHolder Lens 18 mm Focal Length Lens 48 mm Focal Length GlassPlate 2...

Page 6: ...r Movable Mirror Adjustable Mirror Vacuum Cell Vacuum Pump withGauge Rotating Pointer Beam Splitter Compensator Plate Component Holder OS 9255A Precision Interferometer Lens 18 mm Fitted Case 2 Polari...

Page 7: ...m the two slits struck the screen a regular pattern of dark and bright bands appeared When firstperformed Young sexperimentofferedimportant evidence for the wave nature of light Young s slits can be u...

Page 8: ...he mirror a measured distance dm and counting m the number of times the fringe pattern is restoredtoitsoriginalstate thewavelengthofthelight canbecalculatedas 2dm m If the wavelength of the light is k...

Page 9: ...aser see Suggestions for Additional Experiments near the end of the manual To set up and align your PASCO Laser 1 Set the interferometer base on a lab table with the mi crometerknobpointingtowardyou 2...

Page 10: ...ks so that the beam is reflected to the fixed mirror Adjust the angle of the beam splitter as needed so that the reflected beam hits the fixed mirror near its center 4 There should now be two sets of...

Page 11: ...t s at least 12 inches from the edge of the interferometerbase Fringesshouldappearinthebright disk of the viewing screen Fine adjustments of L1 may be necessary to find the fringes A piece of white pa...

Page 12: ...he diffuser rather than on the viewing screen Just place the diffuser where you would normally place the viewing screen and look through it toward the interferometer Tips on Using the Interferometer F...

Page 13: ...nd back surfaces of the mirrors and beam splitter of ten cause minor interference patterns in the back ground of the main fringe pattern These background patterns normally do not move when the mirror...

Page 14: ...rferometerintheMichelsonmode soaninterferencepatternisclearlyvisibleonyour viewing screen See Setup and Operation for instructions 2 Adjustthemicrometerknobtoamediumreading approximately50 m Inthispos...

Page 15: ...ht 2dm N then average your results If you tried the Fabry Perot mode also calculate the wavelength independently for that data The same formula applies PartII 1 From your observations in step 1 of the...

Page 16: ...exactly 1 A graph of index of refraction versus pressure for a gas is shown in Figure2 1 Byexperimentallydeterminingtheslope the index of refraction of air can be determined at various pressures Proce...

Page 17: ...helightnowgoesthroughonelessoscillationwithin the cell This has the same effect on the interference pattern as when the movable mirror is moved towardthebeam splitterby1 2wavelength Asinglefringetrans...

Page 18: ...2 Placetherotatingtablebetweenthebeam splitter and movable mirror perpendicular to the optical path NOTE if the movable mirror is too far forward the rotating table won t fit You may need to loosen t...

Page 19: ...ction of air see Experiment 2 ng the index of refraction of the glass plate as yet unknown 0 the wavelength of your light source in vacuum and N the number of fringetransitionsthatyoucounted Carrying...

Page 20: ...pticalimperfections Thenremovetheviewing screenandreplacethelaserwiththespectrallight source Iffringesaren tvisiblewhenlookingintothe beam splitter proceedasfollows a Tape two thin pieces of wire or t...

Page 21: ...ate the Micrometer Knob fully IN before storing the Interferometer MicrometerCalibration The micrometer is calibrated before it is shipped How ever ifrecalibrationbecomesnecessary usethefollowing proc...

Page 22: ...03956 MovableMirror 003 03955 ComponentHolder 003 05161 Compensator 003 03958 InterferometerManual 012 05187 VacuumPump OS 8502 Component Part No VacuumCell 003 05162 RotationalPointer 003 05160 Fitt...

Page 23: ...imitingfactorsareplayinthesystemanduncertainty inourmicrometerposition 6 Losingcountoffringes andinexactpositioningofthe fringes relative to our reference mark 7 In order to interfere the two light be...

Page 24: ...e vacuum first then count the fringes as the vacuum was released The average slope starting at a guage reading of 60 was 3 462x10 6 0 9995 0 9996 0 9997 0 9998 0 9999 1 1 0001 1 0002 1 0003 1 0004 1 0...

Page 25: ...drews Prentice Hall 1960 is Thesecondtermisnegligibleforvisiblewavelengths and may be ignored Notes General It is often difficult to count large numbers of fringes due to eyestrain If you find this to...

Page 26: ...com web www pasco com Contacting Technical Support Before you call the PASCO Technical Support staff it wouldbehelpfultopreparethefollowinginformation If your problem is with the PASCO apparatus note...

Page 27: ...PrecisionInterferometer 012 07137B 24...

Reviews: