5. OVERVIEW OF HEATERS DESIGN
Fuel System : This heater is equipped with an electric
air pump that forces air through the air
line connected to the fuel intake and then
through a nozzle in the burner head.
When the air passes in front of the fuel
intake it causes fuel to rise from the tank
and into the burner nozzle. This fuel and
air mixture is then sprayed into the
combustion chamber in a fine mist.
“Sure Fire Ignition” : The electronic ignitor sends voltage to a specially designed spark plug.
The spark plug ignites the fuel and air mixture described above.
The Air System : The heavy duty motor turns a fan that forces air into and around the combustion
chamber. Here the air is heated and then forced out the front of the heater.
The Safety System :
A. Temperature Limit Control :
This heater is equipped with a
t
emperature
l
imit
c
ontrol designed to turn
off the heater should the internal temperature rise to an unsafe level. If this
device activates and turns your heater off it may require service.
Once the temperature falls below the reset temperature you will be able to start your heater.
B. Electrical System Protection : The heaters electrical system is protected by a circuit breaker mounted to
the power switch that protects the PCB assembly and other electrical
components from damage. If your heater fails to operate check this fuse
first and replace as needed.
C. Flame-Out Sensor :
Utilizes a photocell to monitor the flame in
the
burn chamber during normal operation.
It will cause the heater to shut-off should the burner flame extinguish.
6.
DO NOT OVERFILL YOUR HEATER AND BE SURE HEATER IS LEVELED.
IMPORTANT
NOTICE REGARDING FIRST IGNITION OF HEATER :
The first time you light the heater, it should be done outdoors. This allows the oils, etc. used in
manufacturing the heater to burn off outside.
WARNING!! :
NEVER REFILL HEATER FUEL TANK WHEN HEATER IS OPERATING OR
STILL HOT.
8
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
Internal Shut-Off Temp.
Reset Temperature
MODELS
Plus/Minus 10 Degrees
Plus/Minus 10 Degrees
IH75000
110˚(C)/
230˚
(F)
90˚(C)/
194˚
(
F
)
IH125000
70˚(C)/
158˚
(F)
40˚(C)/
104˚
(F)
IH170000
70˚(C)/
158˚
(F)
40˚(C)/
104˚
(F)
FUSE TYPE:
All Models
250 volt / 5 amps
FUELLING YOUR HEATER
NEVER FILL THE HEATER FUEL TANK IN THE LIVING SPACE : FILL
THE TANK OUTDOORS.