It is advisable to set the temperature of the water in the boiler between 60 ° C and 70 °C.
Briefly press key "4" to exit programming or wait a few seconds for the automatic return
to the working position or rest.
During the work phase, if the water temperature in the boiler is much lower than the set
value, the stove works at the maximum power level set. On the other hand, when the
temperature of the water in the boiler approaches the set value(difference of less than 5 °
C) the stove gradually decreases the power level. If despite the power reduction the
water temperature in the boiler continues to rise and reaches the set temperature, the
word "MODULA" (reaching the temperature) may appear on the bottom line of the
display.
It is advisable to always set the power of the Idro stoves to its maximum value "5".
PUMP
In the hydro models there are a pump and an expansion tank for direct connection of
the stove to the radiator system. The circulator starts as soon as the water reaches a
temperature of 50 ° C and turns off when it drops to 49 ° C.
OFF
To off the stove, hold down key “4” for a few moments.
Upon receipt of the switch-off signal, the message “FINAL CLEANING” will appear on
the display while the smoke suction fan continues to operate at maximum speed for a
minimum time of about 10 minutes to ensure complete cooling of the stove. The hot air
fan also continues to operate until the stove cools down and turns off.
ATTENTION: Never disconnect the power supply at this stage.
NO IGNITION - ALARM
If the ignition of combustion is not detected, the message "AL 5 NO IGNITION"
appears on the display. To deactivate the alarm state, press the SET button (4) for a
long time (approx. 2 seconds). The alarm stops and the stove first returns to the
"FINAL CLEANING" state and then to "OFF".
Before starting a new ignition cycle, the causes must be checked:
• Check that the tank is full
• Check that the brazier is in the correct position
Then, remove the unburned fuel from the brazier.
ATTENTION: An excessive quantity of fuel in the brazier, a wet fuel or a dirty brazier
make the ignition phase difficult. In the presence of these critical conditions a dense
white smoke can form, capable of causing an explosion in the combustion chamber,
such as to shatter the glass.
Warning: never stand in front of the stove during the ignition phase if the fuel releases
dense smoke.
In any case, the stove is equipped with all the safety systems necessary to reduce the
risk of glass breakage to a minimum.
If the appliance does not turn on regularly, the main cause may derive from insufficient
maintenance or poor quality of the fuel used. Clean as explained in the dedicated
chapter.
22
Summary of Contents for SOFIA
Page 1: ...Produzione stufe e termostufe a pellets e policombustibili User manual SOFIA Ermetic Stove ...
Page 21: ...Motherboard Connections 18 ...
Page 27: ...CONSOLE 24 5 DISPLAY 5 1 ...
Page 28: ...28 25 ...
Page 29: ...USER MENU 26 5 2 USER MENU ...
Page 30: ...USER MENU 09 Technical menu 10 Abilita combustibile 11 Tipo combustibile under key 1 2 27 ...
Page 31: ...USER MENU 28 ...
Page 32: ...USER MENU 29 ...
Page 33: ... and so on up to PROGRAM 4 USER MENU 30 ...
Page 34: ...USER MENU 31 ...
Page 50: ...47 ...