38
Cantinola Touch 2016 operating and maintenance manual
MAINTENANCE
GENERAL RULES
The boiler is to be maintained in cold condition, in order to avoid both burns and
thermal shocks.
Before starting, disconnect the power supply.
To ensure a correct use and function of the boiler and provide a cleaning periodically
by a qualified technician preferably.
OPERATIONS TO BE CARRIED OUT BY THE USER
Cleaning and maintenance to be carried out every day before turning the boiler
on
Using a vacuum cleaner:
Open the door and vacuum the fire bed (pic 1)
Take off the crucible, check that it is clean and clean the holes
Vacuum clean the crucible compartment, clean the contact edges and insert the
crucible back in.
Clean the pellet slide using the brush provided (pic 2) and then vacuum clean to eliminate
the fuel residues. This allows pellet to flow to the crucible without any obstacles,
avoiding the fuel to accumulate on the slide.
Pic 1 Pic 2
PERIODICAL CLEANING AND MAINTENANCE
The cleaning frequency is indicative and can reduce or increase according to fuel
quality and operating conditions (e.g. repeated turning on and off).
-
Week
To clean the smoke exchanger pipes using the mobile turbolators driven by the rod on
the front. Move it back and forth 5 to 10 times (pic 3).
Clean the combustion chamber and the ashes drawers (pic. 4, 5 and 6), removing the
residues fallen during the functioning.
Pic 3