8
Manual use and maintenance _2016
Manuale uso e manutenzione Cantinola Touch 010015 del 28/04/2016
-
Circulator
-
Membrane expansion vessel
-
Electronic unit control, complete of panel and 3 temperature probes.
Smoke temperature
Water boiler temperature
-
Safety valve (3 bar)
-
Smoke Draught Pressure sensor
-
Manometer for checking the loading pressure (not more than 1,5 bar)
-
Water pressure sensor
-
Smoke extractor
-
Automatic cleaning system of smoke pipes
-
Ash collecting box
As an option, the boiler can be equipped with a circuit for the production of hot sanitary water
complete of the following additional parts:
- Hall effect flow switch
- Three-way diverter valve
- 16 heat-exchanger plates for the production of hot sanitary domestic water
- Tank and feeding system for a bigger autonomy
- GSM system for a remote control
- Remote display
Technical features
Model
Cantinola Touch 24
Cantinola Touch 29
29
Power heart
Min / Max [kW]
6,76 / 23,21
6,76 / 29,00
Water efficiency
Power Min / Max [%]
89,51 /90,38
89,51 / 90,05
Nominal heat power
Min /Max heating [kW]
6,1 / 21,0
6,1 / 26,1
Combustible
Type
Pellet
Pellet
Tank Capacity
[Lit / Kg-Pellet]
59/34
59/34
Extension capacity
[Lit / Kg-Pellet]
56/32
56/32
Info
Water capacity[lit.]
47
47
Option
Hot sanitary water
production
Hot sanitary water production