③
Lock will check the lock ID and key of the user card (or any form of user key).
④
Lock will emit Green LED and beep sound once.
⑤
Bolt will be moved and locker will open.
⑥
User information will be erased from the lock so that new user can use the
empty lock.
☞
In free selection mode, lock and card needs to read and write the each
other’s information. So please do not sway the card until the latch is moved.
3.3.2 Replacing old User card with New User card
(1) Free Selection
①
Issue new user card by LOS (Locker Operation System) program.
②
In case the locker is closed, put
Master card
to the lock to open the lock.
③
Put new User card to the lock, then lock will accept new User card, and missing
card will not be accepted.
④
In case the locker is opened, just put the new user card to the lock, and the
lock will register this locker number. Old User key will not be accepted.
3.4 Low Battery warning and battery change
In the RFID lock, 4 pieces of 1.5V AA alkaline batteries are used.
When battery reaches to low voltage ;
①
Beep sounds five times.
②
Red LED lights
③
Low battery is recorded in the memory of
the User Card (Operator can know the low
battery of the lock when the card is read at
operator’s Program).
When low battery warning sign is displayed, please change the battery.
①
Open the battery case at main case.
②
Change four batteries.
③
When you pull out the battery, and do not insert the batteries in 3 minute, the
Version 1.2