System Description
© PAT
Rev. D 04/12/02 CSH
190072_d.DOC
7
After pushing the “Tare Button” (7) the load display is set to zero (taring) and
the control light lights up. After lifting a load the display shows the
net load
(pay load).
The
net load
display will change to the actual load display when the boom
radius is changed (either by angle or length).
Button
"LIMITS"
Button to start the function "program limit values".
For the proceeding please refer to
⇒
chapter 5.1.
Button
"SELECT"
Button to start the function "set operating mode".
For the proceeding please refer to
⇒
chapter 4.1.
The correct setting is of utmost importance for the proper function of the system and the
crane. Therefore only operators who are thoroughly familiar with use and operation of the
system shall set this button.
Button
"INFO"
Button to start the function "information crane configuration"
Please refer to
⇒
chapter 5.2.