Operator's Manual
DS 350 / 1334
© PAT
Rev. D 04/12/02 CSH
190072_d.DOC
8
Button
"CONTROL"
Button to start additional functions.
Please refer to
⇒
chapter 5.3.
Audible
Alarm
The AUDIBLE ALARM (12), sounds during the following conditions:
•
overload condition
•
approaching two-block condition
•
preset limits reached
•
malfunction of the RCL system
•
operating error
The alarm can be temporarily silenced by pushing the button “Alarm Stop” (6).
Key
Switch
•
The
anti-two-block
switch kick-out function is deactivated when the KEY
SWITCH (13) is turned to position "B"
and
the “By-pass A2B” button (14) is
pushed.
or
•
The
RCL
kick-out function is deactivated when the KEY SWITCH (13) is
turned to position "B"
and
the “By-pass RCL” button (15) is pushed.
KEY SWITCH (13) can be operated only by using the matching key.
Since button (14) and (15) deactivate the kick-out function of the RCL system / the anti two-
block system, the following instructions must be obeyed:
•
The by-pass function shall be used with discretion, as unwarranted use of it to override
the control lever lockout system can result in harm to the crane and danger to property
and persons.
•
Never use the by-pass function to either overload or operate the crane in a non-permissible
range.