System Description
© PAT
Rev. D 04/12/02 CSH
190072_d.DOC
3
3.1
System Function
Upon switching on, the system starts with an automatic test of the RCL system,
of lamps and audible alarm. During the test, the LC display shows the initial
logo.
If the system was turned off for more than two hours, the setup configuration
has to be entered after the system test. (
⇒
chapter 4)
First, the operating mode is determined by an interactive step-by-step
interrogation of the rigging states.
Next is the interactive input of the reeving.
Now the LC display shows in symbols all inputs and awaits acknowledgment or
canceling.
Upon acknowledgment of the inputs the system is ready for operation.
3.2
Operating Console
The console has 3 functions:
•
inputs by the crane operator (operating mode, reeving)
•
input of geometry limit values and signalization of exceeded limit values
•
display of important data and information
The operator’s console is mounted in the crane’s cab in the operator’s field of vision. For a better
identification of displays and operating elements, they are continuously backlit during operation.