CONFIGURATION SETUP
© PAT Rev. 7 06/18/01 // MO
191319_7.DOC
11
4 CONFIGURATION SETUP
The LMI setup procedure allows the operator to input the crane configuration using interactive
displays. The operator must complete the setup procedure for the Load Moment Indicator system if
the system has been turned off for more than two hours or the crane operation configuration has been
changed.
4.1
LMI SETUP PROCEDURE
...starts:
automatically
, if the system was turned off for more
than two hours.
manually
at each modification of the crane
configuration by pressing key (9) "SEL"
...is operated:
keys F1...F4 in accordance with the actual configuration of the
crane.
...is cancelled:
however, is only ready for operation, if the procedure has
been completed and the inputs have been confirmed.
If the system is turned off, for example during short breaks (less than 2 hours), all adjustments remain
stored. When turning on again the system these adjustments can be acknowledged by merely
pressing one key (provided that the crane configuration has not been modified!).
During the programming procedure the Load Moment Pre-Warning Light (3) and the Load Moment
Limit Light (2) will light up and the aggravating crane movements will be interrupted.
Note:
If a configuration is selected which is not available, the display will indicate error code E04. In
this case, the procedure has to be repeated with valid values!
The correct setting is of utmost importance for the proper functioning of the system and the
crane. Therefore, only operators who are thoroughly familiar with the crane and the
operation of the system should execute the setting of the system according the operating
configuration of the crane.