Error Codes
© PAT
Rev. - 12/18/00 // CSH.
190118_-.DOC
5
5.2
Lockout Function Errors 07 and 08
These errors are caused by defects around the function lockouts.
Error
Code
Error
Cause
Elimination
E07
Faulty acknowledgment
of the overload relay on
the connection board.
The relay should be
energized, the 2nd
contact however is
indicated to be off, or the
2nd contact is indicated to
be on while the relay
should be de-energized.
•
Overload relay or main
board are defective
•
Processor board
defective
•
Replace main board
•
Replace processor board.
E08
No acknowledgment from
the anti-two-block relay
•
refer to E07
•
refer to E07
5.3
Analog Input Channel Errors
These errors occur if the input signal of an analog input channel falls below (E1x) the minimum (4 mA)
or exceeds (E2x) the maximum (20 mA).
The analog channels are used as follows:
Sensor
Pins Terminal X1 Lower Limit Upper Limit
Main Force Transducer
36 E14
E24
Angle Sensor
(Main Boom)
29 E15
E25
Each channel is constantly being monitored to be within 4 mA (1.1V resp.) and 20 mA (5.5V resp.). If
it exceeds these limits, the following errors are triggered:
Error Code Error
Cause
Elimination
E14
Fallen below the
lower limit value in
the main force
channel
•
Cable between the central
unit and force transducer
defective or water inside the
plugs
•
Check cable as well as
plugs, replace, if need be.
•
Force transducer is
defective.
•
Replace force transducer
•
Electronic component in the
measuring channel is
defective.
•
Replace LMI module(s).
E24
Upper limit value in
main force
transducer
measuring channel
has been exceeded
•
refer to E14
•
refer to E14
E15
Fallen below lower
limit value in
measuring channel
"angle main boom"
•
Cable between central unit
and the angle sensor
defective or loose. Water
inside the plugs.
•
Check cable as well as
plugs, replace, if need be.
•
Angle sensor defective
•
Replace angle sensor