Error Codes
© PAT
Rev. - 12/18/00 // CSH.
190118_-.DOC
7
Error Code Error
Cause
Elimination
E47
Error in the
monitored write/
read memory.
The CRC
verification of the
monitored
write/read memory
provides an
incoherent result
•
The CRC sign of the monitored
write/read memory is wrong
•
The buffer battery is discharged
(< 2V at 1kOhm).
•
Processor board defective.
•
Restart the LMI
•
Replace buffer battery on
the LMI main board
•
Replace processor board.
E48
Cyclic RAM test:
error in the internal
write/read memory
(RAM) of the
computer
component 80C537
•
Computer component 80C537
defective
•
CPU module defective
•
Processor board defective.
•
Replace computer
component 80C537.
•
Replace CPU module
•
Replace processor board
with CPU module.
E51
Error in the data
EPROM or
EEPROM.
•
No valid data in the data
EEPROM.
•
Memory module wrongly
bridged.
•
Crane data EPROM defective
•
Load data EEPROM
containing valid data.
•
Bridge memory module
acc. to memory type
•
Replace crane data
EPROM
E56
Error in the data
EEPROM.
•
Memory module wrongly
bridged.
•
Crane data EEPROM defective
•
Bridge memory module
acc. to memory type
•
Replace crane data
EEPROM
E57
Error in serial crane
data EEPROM.
•
Serial crane data EEPROM
does not contain valid data.
•
Memory module defective
•
Write data on the serial
crane data EEPROM (by
means of test program or
on-line function), then
restart the LMI
•
Replace memory module.
E58
Error in the serial
analog data
EEPROM.
•
No valid data in the serial
analog data EEPROM.
•
LMI module(s) defective.
•
Write data on the serial
analog data EEPROM by
means of the test
program, then, restart the
LMI
•
Replace LMI module(s).
E60
The number of the
selected EPROM
•
Load chart EPROM defective
•
Replace load chart
EPROM
base and the
programmed value
are not identical
•
Base number not programmed
•
Program the correct base
number (1 for base 1, 2
for base 2)
•
Load chart EPROM wrongly
programmed
•
Check base programming
in the load chart EPROM.
E71
Faulty
acknowledgment of
relay K1 on the
connection board
•
Relay K1 or main board
defective.
•
Replace main board.