35
Unit Setup
...Port Setup
On/Off selection list
The options in this menu are used
to set how the guidance trace is
turned on/off when doing a
guidance job. Turning the trace
recording on and off when turning
in the head land can give a more
accurate coverage area reading
for the recorded data.
N.B.
On/Off type will be set automatically if an implement that has been setup in
WebTrack has been selected from the Implement option in Recording Details.
Switch -
(On/Off in WebTrack)
– This type uses a manual switch (i.e. rocker
switch) which is connected to the unit that creates an electrical connection when
in the on position, to turn the trace recording on and off.
On Screen
- (Use Arrows in Webtrack)
– When this type is set the trace
recording can be turned on and off by the operator using the Recording on/off
button on the guidance screen.
AlwaysOn
- This sets the trace recording to continually record and can not be
turned off.
SwitchReversed -
(On/Off Reversed in WebTrack)
– This type uses a manual
switch (i.e. rocker switch) which is connected to the unit that creates an electrical
connection when in the off position, to turn the trace recording on and off.
Controller
-
This option is used if the BlackBox is connected to an implement
controller when working with VRT or auto shut off, the trace recording on/off will
be controlled by the controller. For example when the implement is working the
trace will be on and when not working the trace will be off.
Summary of Contents for BlackBox 510