background image

POWER

Blue

. Steady glow indicates power supply is 

OK. Off indicates no power.

IDENTIFY

Blue.

 Blinks when identify is active.

DMX INPUT 

A/B

Amber

. Steady glow indicates port latched to 

active DMX source. Input and Output off on all 

ports indicates no DMX source.

DMX OUTPUT 

A/B

Green

. Steady glow indicates port is transmit-

ting DMX. Input and Output off on all ports indi

-

cates no DMX source.

NETWORK 

LINK/ACT

Green

. Flickering glow means active Ethernet 

network link. Off indicates no network link.

Model 6822 2-Port Gateway

Manual

11/06/20

The Pathport® 6822 2-Port Gateway provides the full 

functionality of other Pathport gateways in a compact, DIN-

rail mountable form factor.
System integrators can now easily put fully customized 

universes of DMX where they’re needed. 
Ideal for use in NEMA enclosures. Fully compatible with 

eDIN interfaces.

The Pathport 6822 features terminal strips that can be removed 

from the card to facilitate easy wiring installation or replacement. 

Make the following connections, 

WITH THE POWER TURNED 

OFF.

POWER

The 6822 is designed to run on either Power-over-Ethernet (PoE), 

or on an auxiliary power supply providing between 18 and 48 volts 

DC. The gateway is Class 1 PoE and will draw up to 4 Watts.
If an auxiliary supply is used, observe the correct polarity when 

connecting V+ and V-. A second set of terminals are provided so 

power may be daisy-chained to other cards. The earth ground 

terminal must be connected to the enclosure’s chassis or electrical 

ground terminal to ensure EMC compliance.

DMX512

DMX connections consist of a shield and data pair. Connect DATA+ 

and DATA- to D1+ and D1-. Observe the same polarity convention 

throughout the system. Connect the cable shield or common to the 

SHLD COM terminal.

NETWORK

All network wiring should follow standard Ethernet rules and be 

installed by a qualified person. As part of the installation, all wiring 

should be certified under the TIA/EIA-568 standard.

OVERVIEW

CONNECTIONS

STATUS INDICATORS

NC

NC

D1+

COM SHLD

D1-

DMX - 

A INPUT

DMX PORT A

NC

NC

D1+

COM SHLD

D1-

V+

V-

GND EAR

TH

V-

DMX - 

A OUTPUT

DMX - B INPUT

DMX - B OUTPUT

AUX POWER IN

18 - 48VDC MAX 4 W

DMX PORT B

V+

POWER

NET
 LINK / 

ACT

IDENTIFY

POWER IN (If PoE not in use):

18-48VDC, 4W Supply required.

Use #1001-100-48-DIN PSU or equal.

Fastening mechanism designed

for 35 x 7.5mm DIN rail

DMX512 INPUTS/OUTPUTS (2)

LED INDICATORS

Female RJ45

Ethernet Connector