January 2021
36
Pathport® OCTO - 64XX - Manual
STRAND ShowNet (UNSECURED)
Check this box to enable the receiving of Strand ShowNet. You must check both the
Allow Unsecured Protocols
checkbox and this checkbox to use Strand ShowNet.
NETWORK DMX TRANSMIT PROTOCOL
TRANSMIT PROTOCOL
Use the drop-down menu to select the network protocol the OCTO will transmit. Options are:
Pathport
will use transmit using unsecured Pathport Protocol.
Art-Net
will use transmit using unsecured Art-Net.
Strand ShowNet
will use transmit using standard, unsecured E1.31 sACN.
E1.31 sACN
will use transmit using standard, unsecured E1.31 sACN.
Pathway ssACN
will use Pathway’s secured sACN for transmitting to the network.
ssACN PASSWORD
Applies only if Pathway ssACN is chosen in the drop-down menu above.
Specifies whether to use the
Domain Auto
or a
Custom
ssACN Transmit password.
REMOTE MONITORING AND MANAGEMENT
For details on how to connect Pathway devices to a SixEye portal, see the
SixEye PROPERTIES
section in the
Pathscape
manual
.
SixEye PROVISION
This button will open the SixEye Provision window. In this field, paste the SixEye Device Key and click
Provision
.
Summary of Contents for Pathport OCTO 64 Series
Page 7: ......