background image

POWER IN

Blue

. Glowing steadily indicates power supply OK; 

off indicates no power.

PROCESSOR

Green

. Glowing steadily indicates processor is 

OK; off when POWER IN is lit indicates processor 

failure.

DMX INPUT

Amber

. Glowing steadily indicates data signal 

received; off indicates no signal present.

MENU 

FUNCTION

Amber. 

Indicates  which  function  is  active  on  the 

numeric display.

ISO INPUT

Red

. Steady glow indicates isolated 5V supply is 

OK. Off indicates no power.

OUTPUT

Amber

. Glow approximates output level.

DMX Interface - PWINF DIN PWM4A / PWM6A

6-Channel PWM DC Dimmer

Manual

08/31/21

The Pathway eDIN LED Dimmer/DC Driver provides DMX512 

control over LEDs and other DC devices. Each module 

provides 6 channels of control. When controlling LEDs, the 

module acts as a dimming interface only. The LED fixture 

will require a separate regulated DC power supply, as 

recommended by its manufacturer.
These instructions apply to REV 2 hardware running 

firmware 1.6.2 or higher.

The PWINF DIN PWM features terminal strips that can be removed 

from the card to facilitate easy wiring installation or replacement. Make 

the  following  connections, 

WITH THE POWER TURNED OFF

,  and 

observe ESD precautions by ensuring the installer is properly grounded 

before handling the device.

POWER

The DMX/RDM Splitter is designed to run on a range of voltages from 

9-30 volts DC. Each PWM DC Dimmer requires 5 watts. Observe the 

correct polarity when connecting to V+ and V-.
A  second  set  of  terminals  are  provided  as  a  DC  power-through 

connection to other DIN devices. The EARTH GND terminal may be 

connected to the enclosure’s chassis or electrical ground terminal to 

improve EMC compliance.

DMX512

DMX connections consist of a shield wire and one or two data pairs. 

DMX IN is wired from the control console, or other source. DMX THRU 

may be daisy-chained to the DMX IN of other eDIN cards, or to other 

DMX equipment. 
Connect DATA+ and DATA– wires to D1+ and D1- respectively. The 

optional data pair may be connected to D2+ and D2-. Observe the same 

polarity convention throughout the system. Connect the shield wire to 

the SHLD/COM terminal.

DC/PWM OUTPUTS

The LED Dimmer/DC Driver interface provides six (6) outputs that will 

each handle up to 4 amps at voltages up to 30VDC. The outputs are 

of the current-sinking type. A separate DC power supply is required, 

OVERVIEW

CONNECTIONS

STATUS INDICATORS

appropriately sized for the connected load, as recommended by the 

connected equipment’s manufacturer.

Each output is fully opto-isolated from the other outputs, from the 

DMX signal and from the eDIN board power supply. Multiple pins 

are provided to allow for load spreading. Outputs are connected 

as follows:

LOAD- 

(Terminals 1 & 2): Connects to the negative terminal of 

the load, or the LED Cathode.

V- 

(Terminals 3 & 4): Connects to 

the negative or common terminal 

of the load power supply.

V+ 

(Terminals 5 & 6): Connects 

to the positive terminal of the load 

power supply and to the positive 

terminal of the load, or the LED 

Anode.

OUTPUT 1

TERMINA

TE

LOAD-

V-

IN

OFF

IN

V+

DMX THRU

ISO 5V

DMX

DMX IN

D2-

D2+

D1-

D1+

D2+

SHLD

ON

COM

D2-

D1+

COM SHLD

D1-

POWER IN

PROCESSOR

DMX INPUT

TEST

ADDRESS

UTIL

MODE

LED/DC DRIVER eDIN 6 CHANNEL

ENTER

V-

V+

V-

GROUND EAR

TH

V+

1

5

3

2

4

1

5

3

2

4

1

5

3

2

4

1

5

3

2

4

6

IN

V+

V+

IN

V+

IN

IN

V-

LOAD-

OUTPUT 2

6

4

2

3

5

1

V+

IN

V+

IN

IN

V-

LOAD-

OUTPUT 3

6

4

2

3

5

1

V+

IN

V+

IN

IN

V-

LOAD-

OUTPUT 4

6

4

2

3

5

1

V+

IN

V+

IN

IN

V-

LOAD-

OUTPUT 5

6

4

2

3

5

1

V+

IN

V+

IN

IN

V-

LOAD-

OUTPUT 6

6

4

2

3

5

1

6

4

2

3

5

1

RNC

RNO

IN-GND

CCL

1

5

3

2

4

RCOM

AIN1

AIN2

AIN3

AIN4

AIN5

AIN6

OUTPUT RATING

5-30vdc @ 96w MAX

Internally Fused @ 4A/Output

(2 Spare Fuses Inside)

POWER IN

9-30VDC

Max 4 Watts

DMX In from

Control System

Analog Inputs 

(x6)

DMX Thru to

other DIN devices

Contact Closure 

“Panic” Input

Status LEDs

Analog / 

Contact 

Input 

Common

DMX Present 

Relay 

(Normally-open, 

Normally-closed, 

and Relay 

common)

Menu

Function LEDs

Power In:

9-30VDC, 5W Supply required.

Use PWPWR DIN TERM [xxxx]
NOT FOR LED LOADS. Use separate 

power supply for LEDs.
Connect Earth ground to improve 

EMC compliance

End of line 

DMX512 

termination switch

Isolated Solid-state switch outputs (x6)

5-30VDC (External Supply Required)

4A or 6A @ 30VDC Max

4.07”

[103.4mm]

8.0”

[203mm]

1.85”

[47mm]

LED numeric

display

Program

pushbuttons

Fastening mechanism

designed for 35 X 7.5mm 

DIN rail

DIN rail release lever

Use large flat-head screwdriver or 

similar tool to gently pry lever 

away from DIN rail to release